background image

26 

ITEM 

DESCRIPTION 

PART # 

ITEM 

DESCRIPTION 

PART # 

25 

Inner Top 

PS CL60-24160 

42 

Glass Rope 

RP FTV125X1.00GA 

26 

Back Insulation 

N/A 

43 

Door Rope 

RP 7810863KRP 

27 

Cast Iron Access Door  PC CL60-40347 

44 

Glass Holders 

PS CL60-24008 

28 

Inner Back 

PS CL60-24005 

45 

1/4" - 20 x 3/8" Screws 

N/A 

29 

Inner Side 

PS CL60-23999 

48 

Front Insulation 

N/A 

31 

Side Insulation 

N/A 

49 

Front Air Duct 

PS CL60-23996 

32 

Cast Iron By-pass 
Door 

PC CL60-40346 

50 

Top Grill (Gold) 

PO CL60-89797 

33 

By-pass Door Rod 

PO CL60-89707 

52 

Outer Front 

PS CL60-24060 

34 

3/8" x 3/8" Set Screw 

N/A 

53 

Top Insulation 

N/A 

35 

Catalytic Combustor 

PO CL60-89786 

54   Access Door Gasket 

RP 7810863KRB 

36 

Ash Pan 

MA CL60AP 

55 

Flame Impingement Shield 

PS CL60-24053 

38 

Firebrick 

PR 900050 

56 

By-pass Rope 

RP FR2LD.750G 

39 

Log Retainer 

MA CL60-24299 

57 

Grate Slide Plate 

N/A 

40 

Bottom Grill (Black) 

PO CL60-89711 

65 

Steel Baffle Plate 

N/A 

 

 

 

66 

Angle Iron Supports 

N/A 

N/A = PART NUMBER NOT AVAILABLE AT THIS TIME AND IS SUBJECT TO CHANGE 

Содержание AIR-TIGHT

Страница 1: ...ble vapors and liquids in the vicinity of this or any other appliance Manufactured by New Buck Corp Effective April 2003 Spruce Pine NC 28777 IMPORTANT INSTALLATION MUST BE MADE IN ACCORDANCE WITH STA...

Страница 2: ......

Страница 3: ...ION 4 INSTALLATION 5 20 CHIMNEY 5 6 COMBUSTION AIR DUCT 7 HOT AIR DUCT INSTALLATION 7 13 FIREPLACE DIMENSIONS 14 FRAMING IN AND FINISHING 13 17 FAN KIT 18 WIRING DIAGRAM 19 20 OPERATION 20 STARTING A...

Страница 4: ...2...

Страница 5: ...lat Black DISCLAIMER NOTICE The BTU ranges and heating capacity specifications are provided as guidelines only and in no way guarantee the output or capacity of the unit In warmer climates on average...

Страница 6: ...ystem may be used You may connect to a masonry chimney as long as the conditions in section 8 4 5 of NFPA 211 are met The connector from the flue outlet of the BuckMaster and the masonry chimney must...

Страница 7: ...ished hearth In all installations consideration must be given to the thickness of the final hearth material NOTE A clearance of 1 2 minimum must be maintained between the top of the finished hearth an...

Страница 8: ...nnect first chimney section per manufacturer s instructions Continue adding sections until required height is achieved 4 If the chimney is not enclosed and passes through a vented attic space or roof...

Страница 9: ...k of the outside vent and the other end over the fireplace connector 3 Secure duct at each end with clamps supplied 2 8 WARM AIR OUTLETS The two 8 heat duct outlets at the unit top are blocked off dur...

Страница 10: ...TES A In installations where ductwork is run downward one standard hot air vent must also open into the fireplace room B Booster fans must not be enclosed with a chase C Booster fans on upward ductwor...

Страница 11: ...n running ductwork down standard hot air registers must also open into room with fireplace NOTE All hot air ductwork must be 8 diameter B Vent through the initial wall or ceiling penetration Single wa...

Страница 12: ...ster fans and backdraft dampers are installed on upward ducting 2 clearance to combustibles must be maintained around the hot air ductwork NOTE When ducting down attach a 90o elbow to the top of T con...

Страница 13: ...NS 1 Do not install heat registers below the level of the two hot air outlets on the top of the fireplace 2 Do not tie the ducts into a central heating system 3 All hot air ductwork must be 8 diameter...

Страница 14: ...nd into the fireplace hot air outlets Be sure the face of each elbow is parallel to the front of the fireplace 3 Screw grill box extensions onto standard grill boxes using four metal screws Slide gril...

Страница 15: ...verlap the front of the unit more than 2 on the sides to allow proper operation of the doors 5 When the front finish is complete install the hot air outlet grills with screws provided The grills shoul...

Страница 16: ...14 FIREPLACE DIMENSIONS in inches NOTE Rough opening size 38 1 2 WIDE x 52 HIGH...

Страница 17: ...15 NON COMBUSTIBLE FACING CUT OUT DIMENSIONS Required for tile or marble facing SET BACK FOR FACING OPTIONS...

Страница 18: ...16 ROUGH OPENING DIMENSIONS ROUGH FRAMED FLOOR LEVEL INSTALLATION SHOWN WITH OPTIONAL 10 x 10 GRILL KIT HEADER DETAIL ROUGH FRAMED RAISED INSTALLATION SHOWN WITH OPTIONAL 10 x 10 GRILL KIT...

Страница 19: ...eramic tiles stone bricks etc must extend 24 in front of and 8 beyond the sides of the fuel loading door This hearth extension musts be placed on non combustible flooring If this unit is to be install...

Страница 20: ...hree conductors hot neutral and ground 4 Open the electrical box on the fan motor which is located on the left side of the power conduit 5 Run power conduit to switch box Secure with BMX connector not...

Страница 21: ...dle onto shank and insert into door 2 Secure with locking nut 3 Slide on washer and latch cam and secure with locking nut STANDARD WIRING DIAGRAM WITH WALL SWITCH OPTIONAL WIRING Refer to configuratio...

Страница 22: ...duce more creosote which will condense on the glass doors and chimney requiring more frequent cleaning WARNING DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS FIREPLACE...

Страница 23: ...container on a non combustible floor in a garage or outdoors since ashes may remain hot for days and give off toxic fumes Ensure that ashes are completely cool before final disposal Leaving a small am...

Страница 24: ...ed Ceramics Customer Service Department P O Box 29664 Atlanta GA 30359 770 448 6888 See enclosed catalyst warranty for instructions New Buck Corporation does not handle catalyst replacements Customer...

Страница 25: ...e right and remove 3 Open by pass door 4 Reach into the firebox and raise catalytic combustor to top of secondary heat chamber 5 Remove combustor through open by pass door To install new combustor fol...

Страница 26: ...only properly cured woods D Dirty or Blocked Chimney Check and clean as necessary E Chimney Too Short Review chimney specifi cations in this manual and see that your install ation conforms to them 2...

Страница 27: ...Box PS CL60 24033 4 Glass PG CL60 89672 16 Optional 10 x 10 Grill PO CL60 86523 5 Door Handle PO CL60 89712 20 7 32 x 1 Hinge Pin PH 7321LSP 6 Door Handle wood PO CL60 89819 24 Door Latch PO CL60 242...

Страница 28: ...32 Cast Iron By pass Door PC CL60 40346 50 Top Grill Gold PO CL60 89797 33 By pass Door Rod PO CL60 89707 52 Outer Front PS CL60 24060 34 3 8 x 3 8 Set Screw N A 53 Top Insulation N A 35 Catalytic Co...

Страница 29: ...59 Compression Springs PH 141SPRING 60 3 16 Flat Washers PH 316FLW 61 Slide Plate Bracket PS CL60 24010 62 10 24 Lock Nuts PH 1024HNP 63 10 x 1 2 Tek Screws PH 101612TEK 64 Slide Rod MF CL60 22015 65...

Страница 30: ...any labor or transportation charges required Thereafter B Period II For the period after the first year from the date of purchase and extending for 5 years as long as the BuckMaster Stove is owned by...

Страница 31: ...ion of which is not covered by warranty OTHER RIGHTS This warranty gives you specific legal rights and you may also have other rights which vary from state to state OWNER REGISTRATION CARD The followi...

Отзывы: