18
STANDARD FORCED AIR FAN
WIRING OF FAN SHOULD BE PERFORMED
BY A QUALIFIED ELECTRICIAN.
The forced air fan comes factory installed and includes the
prewired motor with fan blade and mounting hardware.
The directions below describes how to wire the fan for a
standard duct system equipped with booster fans and/or
snap disks. Refer to the Wiring Diagrams on pages 19 and
20 for further instructions.
1. Mount a 2" x 4" electrical box on the framing near the
fireplace for installing a switch to control the fan kit.
2. On the left side of the fireplace closest to the switch
location, feed a length of flexible conduit through the
7/8" hole in the sidewall of the fireplace.
3. The conduit must have three conductors: hot, neutral,
and ground.
4. Open the electrical box on the fan motor which is
located on the left side of the power conduit.
5. Run power conduit to switch box. Secure with BMX
connector (not supplied).
6. Run grounded electrical cable from a new or existing 15
AMP circuit to the switch box and connect wires and
switch as shown in wiring schematic.
NOTE: If any of the original wire as supplied with the
appliance must be replaced, it must be replaced with
type 16 ga., 105
o
C. rating wire or its equivalent.
NOTE: Installation and repair should be done by a
qualified service person. This heater should be
inspected before use and at least annually by a
qualified service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, pet hair, etc. It is
imperative that control compartments and
circulating air passageways of the heater be kept
clean.