BTR Controls, Inc
TROUBLESHOOTING
DG-Mini V7 Rev. C Standard HW manual V 1.0.2
61
Table of Error Codes
Error
Code:
Description
Level
Cause:
Check:
OC2
Overcurrent
Medium Priority
The motor current has
exceeded the inverter
rating by 150% for more
than 30 seconds.
Check for mechanical
obstructions.
OC3
Overcurrent
Medium Priority
Over current while
accelerating, the
acceleration is too fast.
Check that the door is not
binding, may need to reduce
the acceleration level using the
menu
System
Config
Ramps
ACC OPEN
OC4
Overcurrent
Medium Priority
Over current while dc
braking operates.
The dc braking is too
aggressive, adjust the DC Break
level and duration using the
menu
Sys Config
Motor
Config
DC Brake
OC5
Overcurrent Peak
High Priority
Severe overload, possibly
permanent damage to
the controller.
Check for a short. Check that
the motor is not stalled. Check
that the brake is releasing. May
need to decrease the boost
level using the menu
Sys
Config
Motor Config
Boost
OH
Controller
Overheated
Fault Specific
Overheating inside the
panel, the inverter is too
hot.
Check ventilation. Check that
current limits have not been
exceeded.
HE
12V Supply Shorted
Fault Specific
HE
24V Supply Shorted
Fault Specific
Low internal 12V or 24V
supply.
Check I/O wiring for short or
overload.
E01
Mechanical Overload
Low Priority
Mechanical overload
(slip monitoring) or
missing signal from the
encoder.
Check the encoder wiring.
Check that the motor is not
stalled. Check for possible
mechanical obstruction.
E02
Direction Error
Low Priority
Direction error.
Check encoder wiring. Rerun a
Quick Setup.
Confirm that the pulses count
up while opening and down
when closing the door.
E03
No Encoder Signal
Low Priority
No signal from the
encoder - (only during
installation).
Check the wiring related to the
encoder, and any possible
mechanical obstruction.
E04
Speed Error
Low Priority
Speed error
Check the wiring related to the
encoder, check gear ratio.
E05
Ref. Connection Error
Medium Priority
The reference switch is
shorted or broken.
Check the reference switch.
E06
Ref. Switch Position
Error
Medium Priority
The reference switch
operates in the wrong
position.
If using an incremental encoder
the reference switch has
activated at the wrong position,
Содержание DG-Mini
Страница 1: ...DG Mini Rev C Standard HW manual V 1 0 0 1 DG Mini Universal Door Control ...
Страница 25: ...BTR Controls Inc MENU NAVIGATION DG Mini V7 Rev C Standard HW manual V 1 0 2 25 MENU TREE ...
Страница 65: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 65 DG Mini 1500G ...
Страница 66: ...BTR Controls Inc SPECIFICATIONS DG Mini V7 Rev C Standard HW manual V 1 0 2 66 MECHANICAL DIMENSIONS ...
Страница 68: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 68 APPENDIX ...
Страница 69: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 69 ...
Страница 71: ...BTR Controls Inc APPENDIX DG Mini V7 Rev C Standard HW manual V 1 0 2 71 ...