![Bryant 581J Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/bryant/581j/581j_product-data_2822131003.webp)
3
FEATURES AND BENEFITS
S
Single--stage cooling capacity control on 04 to 07 models
S
Two--stage cooling capacity control on 08 and 09 models
S
SEER up to 15.6
S
EER up to 13.0
S
IEER’s up to 13.0
S
Exclusive non--corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or
center drain
S
Gas efficiencies up to 82%
S
Induced draft combustion design
S
Redundant gas valve, with up to 2 stages of heating
S
Pre--painted exterior panels and primer--coated interior panels tested to 500 hours salt spray protection
S
TXV refrigerant metering system on each circuit
S
Fully insulated cabinet
S
Exclusive IGC solid--state control for on--board diagnostics with LED error code designation, burner control logic and
energy saving indoor fan motor delay
S
Dedicated 3--5 ton “Low NOx” models available that meet California Air Quality Management NOx requirement of 40
nangram/joule or less. Low NOx models include stainless steel heat exchangers
S
Cooling operating range up to 125
_
F (52
_
C), and down to 35
_
F (2
_
C) standard
S
Access panels with easy grip handles
S
Innovative , easy starting, no--strip screw feature on unit access panels
S
Two--inch disposable return air filters
S
Tool--less filter access door
S
Belt drive evaporator--fan motor and pulley combinations available on all three phase models
S
Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
S
New terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
S
Field Convertible from vertical to horizontal airflow for slab mounting. No special kits required
S
Provisions for thru--the--bottom power entry capability as standard
S
Single point gas and electric connections
S
Full perimeter base rail with built--in rigging adapters and fork truck slots
S
Scroll compressors with internal line--break overload protection
S
24--volt control circuit protected with resettable circuit breaker
S
Permanently lubricated evaporator--fan motor
S
Totally enclosed condenser motors with permanently lubricated bearings
S
Low Pressure switch and high--pressure switch protection
S
Exclusive IGC anti--cycle protection for gas heat operation
S
Solid--state electronic direct spark ignition system
S
Flame roll--out safety protector
S
Liquid line filter drier on each circuit
S
Standard Warranty: 10 yr. aluminized heat exchanger, 15 yr. stainless steel heat exchanger, 5 yr. compressor, 1 yr. parts.
581J
Содержание 581J
Страница 51: ...51 TYPICAL WIRING DIAGRAMS C08518 Fig 15 1 Stage Cooling Typical Power Diagram 581J ...
Страница 52: ...52 TYPICAL WIRING DIAGRAMS cont C08577 Fig 16 2 Stage Cooling Typical Power Diagram 581J ...
Страница 53: ...53 C08524 Fig 17 1 Stage Typical Wiring Diagram 581J ...
Страница 54: ...54 C08578 Fig 18 2 Stage Typical Wiring Diagram 581J ...