![Bryant 581J Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/bryant/581j/581j_product-data_2822131016.webp)
16
CURBS & WEIGHTS DIMENSIONS -- 581J04--06
NOTES:
1. DIMENSIONS ARE IN INCHES, DIMENSIONS
IN [ ] ARE IN MILLIMETERS.
2.
CENTER OF GRAVITY
3.
DIRECTION OF AIR FLOW
44
25
636
[
]
18-1/8
459
[
]
12-1/4
312
[
]
14-1/4
363
[
]
16-1/8
411
[
]
SUPPLY
AIR
17-3/4
451
[
]
12-1/8
307
[
]
10-7/8
277
[
]
RETURN AIR
25-5/8
652
[
]
33-3/8
848
[
]
16
406
[
]
1117]
26-1/2
673
[
]
6-1/4
157
[
]
29-3/8
747
[
]
32-1/4
818
[
]
3-3/8
85
[
]
18-1/2
470
[
]
4
100
[
]
ECONOMIZER HOOD
(OPTIONAL)
RETURN
AIR
SUPPLY
AIR
TOP
SEE THRU THE
BASE CHART
E ALT.
CONDENSATE
DRAIN OPENING
IN BASEPAN
C
FLUE
HOOD
W
X
Y
Z
21-1/4
539
[
]
26-3/4
681
[
]
7
177
[
]
RETURN
AIR
25-1/8
638
[
]
10-1/2
265
[
]
SUPPLY AIR
16-3/4
427
[
]
11-3/8
289
[
]
6-1/8
155
[
]
6
152
[
]
31-1/4
793
[
]
6-5/8
168
[
]
1-1/4
32
[
]
RETURN
AIR
SUPPLY
AIR
RIGHT
OUTSIDE
AIR
BAROMETRIC
RELIEF
FLOW
E STD.
CONDENSATE
DRAIN
FILTER
J
30-1/8
764
[
]
8-3/8
213
[
]
74-3/8
1888
[
]
INDOOR BLOWER
ACCESS
CONTROL BOX
ACCESS PANEL
FRONT
F
OPTIONAL
FACTORY
INSTALLED
DISCONNECT
HANDLE
HANDLE
19-1/2
494
[
]
6-5/8
168
[
]
4-5/8
118
[
]
K
46-3/4
1187
[
]
3-3/4
95
[
]
CONDENSER
COIL
LEFT
ELECTRICAL
DISCONNECT
LOCATION
A,
B,
G
D
OPTIONAL
FACTORY
INSTALLED
CONVENIENCE
OUTLET
2-5/8
67
[ ]
BACK
INDOOR COIL
ACCESS PANEL
FILTER ACCESS PANEL
(TOOL-LESS)
TYP
CURB
WIDTH
COMP.
ACCESS
PANEL
CONDENSER
COIL
CONNECTION
SIZES
A
1 3/8" [35] DIA FIELD POWER SUPPLY HOLE
B
2" [50] DIA POWER SUPPLY KNOCKOUT
C
1 3/4" [51] DIA GAUGE ACCESS PLUG
D
7/8" [22] DIA FIELD CONTROL WIRING HOLE
E
3/4"-14 NPT CONDENSATE DRAIN
F
1/2"-14 NPT GAS CONNECTION
G
2 1/2 " [64] DIA POWER SUPPLY KNOCK-OUT
THRU-THE-BASE CHART
THESE HOLES REQUIRED FOR USE
CRBTMPWR001A01, 003A01
THREADED
CONDUIT SIZE
WIRE
USE
REQ'D HOLE
SIZES (MAX.)
W
1/2"
ACC.
7/8" [22.2]
X 1/2"
24V
7/8"
[22.2]
Y *
3/4" (001,003)
POWER 1 1/8" [28.4]
Z**
(003) 1/2" FPT
GAS
1 3/16" [30.0]
FOR "THRU-THE-BASEPAN" FACTORY OPTION,
FITTINGS FOR ONLY X,Y, & Z ARE PROVIDED
*
SELECT EITHER 3/4" OR 1/2"
FOR POWER, DEPENDING ON WIRE SIZE
**
(001) PROVIDES 3/4" FPT THRU CURB
FLANGE & FITTING.
UNIT
J
K
33 3/8
[847]
18 5/8
[472]
41 3/8
[1051]
14 7/8
[377]
41 3/8
[1051]
14 7/8
[377]
581J-04A
581J-05A
581J-06A
C10378
Fig. 1 -- Dimensions 581J04--06
581J
Содержание 581J
Страница 51: ...51 TYPICAL WIRING DIAGRAMS C08518 Fig 15 1 Stage Cooling Typical Power Diagram 581J ...
Страница 52: ...52 TYPICAL WIRING DIAGRAMS cont C08577 Fig 16 2 Stage Cooling Typical Power Diagram 581J ...
Страница 53: ...53 C08524 Fig 17 1 Stage Typical Wiring Diagram 581J ...
Страница 54: ...54 C08578 Fig 18 2 Stage Typical Wiring Diagram 581J ...