Page 10
B
RADFORD
W
HITE
WARNING
All venting must be installed according to this
manual and any other applicable local codes,
including but not limited to, ANSI Z223.1/NFPA 54,
CSA B149.1, CSAB149.2 and ULC S636. Failure
to follow this manual and applicable codes may
lead to property damage, severe injury, or death.
If the system temperatures are unknown at
the time of installation, class IIC or higher
venting material is recommended.
The MagnaTech is a Category IV appliance and
may be installed with the standards listed on
Table 6.
The unit’s vent can terminate through the roof,
or through an outside wall.
All installations must be done following the vent
supplier’s recommended installation techniques.
If these are not available, refer to the Bradford
White recommendations for the material used.
NOTE: For Category IV boilers, have
horizontal runs sloping upwards not less than
1/4 inch per foot (21 mm/m) from the boiler to
the vent terminal; be installed so as to prevent
accumulation of condensate; and, where
necessary, have means provided for drainage
of condensate.
ATTENTION: Pour la catégorie IV, les
chaudières ont horizontal en pente vers
le haut au moins 1/4 de pouce par pied
(21 mm/m) à partir de la chaudière pour
l’évent borne; être installé de façon à éviter
l’accumulation de condensats; et, le cas
échéant, ont des moyens prévus pour
l’évacuation des condensats.
This will allow the condensate to run back to
the MagnaTech to drain. Route the vent pipe
to the heater as directly as possible. Seal all
joints. Provide adequate hangers as required in
the venting system manufacturer’s Installation
Instructions, or at least every 4 feet.
The unit must not support the weight of the
vent pipe. The maximum equivalent pipe
length allowed is 100 feet (30m). Each elbow
Table 5. Vent Accessories
(Place in section 3.1)
Model 1600 Model 2000 Model 2500 Model 3000 Model 3500 Model 4000
Screen for horizontal galvanized air pipe
D2012104
D2012101
D2012101
D2012102
D2012103
D2012103
Screen for horizontal PVC air pipe
CA012004
CA012001
CA012001
CA012002
CA012003
CA012003
Screen for horizontal polypropylene air pipe
CA012204
CA012201
CA012201
CA012202
CA012203
CA012203
Screen for vertical galvanized air pipe
D2012204
D2012201
D2012201
D2012202
D2012203
D2012203
Screen for vertical PVC air pipe
CA012404
CA012401
CA012401
CA012402
CA012403
CA012403
Screen for vertical polypropylene air pipe
CA012604
CA012601
CA012601
CA012602
CA012603
CA012603
Table 3a - Ducted Air Accessories
(Place in section 3.2)
Model 1600 Model 2000 Model 2500 Model 3000 Model 3500 Model 4000
Horizontal vent terminal for stainless steel
D2012004
D2012001
D2012001
D2012002
D2012003
D2012003
Screen for horizontal CPVC vent
CA012104
CA012101
CA012101
CA012102
CA012103
CA012103
Screen for vertical stainless steel vent
D2012304
D2012301
D2012301
D2012302
D2012303
D2012303
Screen for vertical CPVC vent
CA012504
CA012501
CA012501
CA012502
CA012503
CA012503
Table 3* - Vent Accessories
(Place in section 3.5)
Model 1600 Model 2000 Model 2500 Model 3000 Model 3500 Model 4000
Air intake screen for unit placed outdoors
CA0011904
CA011901
CA011901
CA011902 CA0011903 CA0011903
Vent terminal for unit placed outdoors
CA011803
CA011801
CA011801
CA011802
CA011803
CA011803
Table 3** - Air & Vent Accessories for Units Placed Outdoors
Installation Standards
Material
United States
Canada
Stainless steel
UL 1738
Venting must be ULC S636 certified for use as
venting material. The venting material class must
be chosen based upon the intended application
of the boiler, and must be installed according to
the maximum flue gas temperature and the vent
manufacturer’s instructions.
CPVC, sch 40
ANSI/ASTM F441
Polypropylene
Pending APPROVAL
ULC S636 Class 2C
Table 6. Required Exhaust Vent Material
Содержание MagnaTech BMGH1600
Страница 4: ...BRADFORD WHITE ...
Страница 35: ...Page 31 MagnaTech BOILERS AND VOLUME WATER HEATERS ...
Страница 98: ...Page 94 BRADFORD WHITE 1 13 12 4 3 5 13 2 15 Final Assembly DETAIL A 9 10 8 Final Assembly ...
Страница 110: ...Page 106 BRADFORD WHITE 6 2 7 11 1 5 4 12 10 3 3 8 9 6 Control Panel Assembly ...
Страница 114: ...Page 110 BRADFORD WHITE 7 8 15 14 9 4 16 12 5 1 6 2 11 AC DISTRIBUTION BOX ASSEMBLY PART NUMBERS MODELS 2500 AND 3500 ...