AUTOFEED SYSTEM
Consult the original manufacturer’s manual for your chippers
Autofeed operating and maintenance procedures
When processing material through the chipper, the feed system will automatically stop when the
engine drops below a preset RPM point. The engine is constantly being monitored by an adjustable
electronic speed switch. The switch can be adjusted so that at a given RPM, an electronic relay system
will operate the hydraulic solenoid valves to stop the feedwheels until the engine has recovered speed.
The patented “Autofeed Plus” system will reverse the feedwheels for a set period of time and then stop
until the engine has recovered speed. Both autofeed systems will then automatically turn the feed on
to resume forward travel.
Due to required components and equipment options a machine may have various types or brands of
autofeed systems. Each chipper is shipped with the original manufacturer’s manual for the autofeed
system it is equipped with.
For the approximate autofeed settings on all optional autofeed systems refer to page 28 of the chipper
manual. For part numbers on the hydraulic portion of the autofeed systems refer to pages 98 & 99 of
the chipper manual.
Do not power wash the digital tach hour meters. Pressure causes unwarranted damage.
Do not
spray tach, this will void warranty.
AUTOFEED OPTIONS
PART NUMBERS FOR AUTOFEED DIGITAL TACH HOUR METERS
For Service Call
1-81-98-08
ESI Intelli-Feed
Part Number: 900-2908-11
Electronic Solutions
Part Number: 900-2904-85
For Service Call
1-866-6-8622
L.O.R. MFG.
Part Number: 900-2906-82L
For Service Call
1-866-28-012
Miratron Inc.
Part Number: 900-2910-68
For Service Call
1-866-76-689
No longer
used.
No longer
used.
Содержание 1290XP
Страница 2: ......
Страница 17: ......
Страница 39: ...Bandit Copyright 12 07 PAGE 23 MODELS 1290XP 1590 DECALS...
Страница 40: ...Bandit Copyright 12 07 PAGE 24 MODELS 1290XP 1590 DECALS...
Страница 70: ......
Страница 140: ...Bandit Copyright 12 07 PAGE 118 MODELS 1290XP 1590 SERVICE RECORD SERVICE RECORD DATE DESCRIPTION AMOUNT...