Technical data
and start-up
BDC546
52
9
Installation / initial start-up
9.1
Installation and connection of the DC/DC converter
DANGER
High voltage!
Danger of death!
Never touch the HV wires or HV connections without ensuring the absence of voltage
beforehand!
The device may only be connected by a qualified electrician!
Safety installations must never be bypassed or circumvented! Any resulting malfunctions could
have life threatening consequences!
NOTICE
All electrical connections near the device have to be secured with a strain relief in order to
protect the cable and/or the cable tree at the control connector against vibration and
consequential damage.
Ensure that the HV battery used is equipped with a pre-charging unit. Any connection without
pre-charging unit may lead to sparks / voltage peaks and damage to the device!
INFORMATION
Prior to installation, visually check the packing material and particularly the device itself for damage.
Each device undergoes a strict quality and function test at BRUSA before distribution. However, we do
not have any influence on the shipping routes, some lengthy, or loading of our products.
PROCEDURE STEP
ILLUSTRATION / OTHER INFORMATION
1.
Mechanically install the device in its specified
position.
Please refer to the installation instructions
Refer to chapter
---
2.
Establish the grounding connection (1) to the
chassis.
For information on the grounding connection,
refer to chapter
7.2 Earthing / grounding screw
The cable length should be as short as possible.
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...