13
Technical data
and start-up
BDC546
3.3.4
Safety instructions for electrical systems
DANGER
High voltage!
Danger of death!
Never touch the HV wires or HV connections without ensuring the absence of voltage
beforehand!
The device may only be connected by a qualified electrician!
Safety installations must never be bypassed or circumvented! Any resulting malfunctions could
have life threatening consequences!
NOTICE
Never open the device without authorisation! Opening the device (sealed housing) voids any
guarantee and warranty rights immediately!
INFORMATION
When working on an HV grid, the following 5 safety rules must generally be strictly
adhered to:
Disconnect the system from the voltage supply.
Switch off the ignition (if applicable)
Remove the service / maintenance plug and/or turn off the battery main switch
(if applicable)
Remove the fuse (if applicable)
Ensure that the system cannot be restarted.
Keep the ignition key safe in order to prevent unauthorised access (if applicable)
Keep the service / maintenance plug safe in order to prevent unauthorised access and/or
use lockable covers to ensure that the battery main switch cannot restart.
(if applicable)
Ensure that the device is de-energised by means of a suitable voltage tester (note voltage
range!)
Earth and short-circuit the system.
Cover or seal off adjacent live parts.
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...