8.3
Lowside cable
DANGER
High voltage!
Danger of death!
Before starting the manufacturing process, ensure that the power cables are de-energised.
NOTICE
To assemble the cable lugs, an appropriate crimping tool must be used! We recommend the
following crimping tool:
Klauke ultra EK 120 UNV-L
INFORMATION
The cable lugs included in the scope of delivery are to be assembled with cables in accordance with
the following specifications. On request, this process may also be carried out by BRUSA.
For installation of a shielded cable with connection to the shielding braid, refer to chapter
In case of longer cable lengths than 1.5 m consult the manufacturer BRUSA. Chapter
4.5 Manufacturer contact information.
1.
M32 cable fittings (LS)
2.
Cable lug, flat (LS), 95 mm²
Required cable cross section: 95 mm²
Max. cable length between device and connected load/source = 1.5 m
Guide the cable fitting (1) over the power cable.
Square crimping of the cable lug (2).
Each prepared cable has to be checked for proper fitting of the cable lug and if for proper fastening of the
crimping (pull test).
When installing the cables (Lowside plus and minus) in the vehicle, ensure that the spanned area remains as
small as possible and that no sensitive control signals are implemented in between.
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...