Technical data
and start-up
BDC546
40
7.1.5
Pin 11 , pin 12 , pin 14 PFO_VC-, pin 15 PFI_VC-
INFORMATION
If pyrofuses are applied, this function can be activated by means of the PARAM software. For
further information on the function and wiring of pyrofuses, refer to chapter
Internal wiring
Pyrofuses can be connected directly to these pins. If an overvoltage is detected, the pyrofuses are triggered.
The pins 11 and 14 PFO_VC- are internally always connected to pin 2 AUX via a fuse.
The pins 12 and 15 PFI_VC- are open drain connections. If an overvoltage is detected, the two pins
are drawn to GND and the pyrofuses are triggered.
If no pyrofuses are applied, the respective function can be deactivated by means of the PARAM software. The
pins 11, 12, 14 and 15 do not need to be connected in this case.
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...