2-65
Confidential
Electrodes location of the process unit
Fig. 2-13
Faulty registration
<User Check>
• Check whether appropriate paper type is selected on the
driver.
• Install the latest main firmware.
Step
Cause
Remedy
1
Registration rear actuator
coming off
Reattach the registration rear actuator.
2
Laser unit failure
Replace the laser unit.
3
Main PCB failure
Replace the main PCB ASSY.