2-24
Confidential
Print Unable
05
Turn the power off
and then back on
again.
Detected the fuser unit
temperature error.
Print Unable
09
Turn the power off
and then back on
again.
Detected irregular power supply
for more than 100 times.
Print Unable
0A
Turn the power off
and then back on
again.
Detected a fan failure.
Print Unable
0B
Turn the power off
and then back on
again.
An error occurred in the high-
voltage power supply PCB
ASSY while operating.
An error occurred in the high-
voltage power supply PCB
ASSY when the machine was in
the ready state.
Print Unable
2E
Turn the power off
and then back on
again.
Could not communicate with the
cartridge sensor on the machine
side.
Print Unable
3A
Turn the power off
and then back on
again.
A communication error occurred
between the controller and
engine in main PCB.
Print Unable
E0
Turn the power off
and then back on
again.
An error occurred in the ROM
check sum.
Print Unable
E1
Turn the power off
and then back on
again.
Program error
Print Unable
E5
Turn the power off
and then back on
again.
An error occurred during access
to the DRAM in the main PCB
ASSY.
Print Unable
E6
Turn the power off
and then back on
again.
Write error in the EEPROM of
the main PCB ASSY
Error message
Description
Error
codes
Refer
to:
Initial display
Scroll
Содержание HL-B2080DW
Страница 30: ...2 8 Confidential MP models Fig 2 4 Feed from MP tray Eject to back side Back side Front side ...
Страница 152: ...3 43 Confidential 9 17 Filter 1 Release the Hook to remove the Filter from the Air duct Fig 3 38 Hook Filter Air duct ...
Страница 211: ...5 27 Confidential Fig 5 6 K 100 K 1 W 100 K 5 Lattice Total ...
Страница 216: ...5 32 Confidential Test pattern Fig 5 9 ...