4. INSTALLATION
17
4-11-5. Connecting the standing pedal harness (option)
1. Pass the marked tube of the relay harness (1)
into the control box through the hole (2) in the
control box.
2. Connect the relay harness (1) to connector P9 on
the main circuit board (3).
3. Remove the screw (4) which is securing the
ground wires, and then add the ground wire (5) of
the relay harness (1) and re-tighten the screw (4).
(The green-and-yellow wire is the ground wire.)
4. Connect the standing pedal harness (6) to the
relay harness (1).
* Connect the standing pedal harness (6) and the
relay harness (1) inside the control box.
(2)
(6)
(5)
(4)
(1)
(3)
2068Q