HE-8000
5. OPERATION
33
5-4. Program setting method
5-4-1. Program initialization condition
The parameters and memory switches for program numbers 1 to 90 are all set to their default values.
5-4-2. Parameter table
•
The parameter values can be stored independently for each program.
•
The allowable setting range for some parameters may vary from the range specified, depending on the
settings of other parameters.
•
The number of stitches which can be sewn may vary depending on settings for parameters such as zigzag
width and feed length.
•
The zigzag width ratio cannot be set when the rear tack pattern is set to an eyelet pattern.
•
If all underlays have been set, the order of sewing is underlays sewn together, then saw-shape underlays
and then rectangle underlays.
* The cutter operating distance may become smaller depending on the settings for parameter No. 2 (Length
of knife) and parameter No. 3 (zigzag stitch length [multi-working knife]), so in such cases the speed will
be reduced automatically.
No.
Setting items
Setting range
Unit
Default
00
Sewing speed (zigzag part)
1,000 – 4,000 rpm
100
3,600
01
Buttonhole/Straight bar tack
0:
1:
2:
3:
4:
0: Buttonhole (free)
1: Buttonhole (rectangle)
2: Buttonhole (radial)
3: Buttonhole (round)
4: Bar tack
1
02
Length of knife
4.0 - 32.0 mm
However, when panel DIP
switches B-3, B-4 or B-5
are at OFF, OFF and ON
respectively when initializa-
tion is carried out, the initial
value will be set to 6.0.
0.1
13.0
(6.0)
03
Zigzag stitch length (multi-working knife)
OFF: Single working knife
4.0 - 69.0 mm
However, the setting range
will be limited by the work
clamp size setting value
which has been set by the
B panel DIP switches.
0.1
OFF
04
Zigzag pitch
0.10 - 2.00 mm
0.025
0.350
1437Q
1438Q
1439Q
1440Q