5-59
Confidential
1.3.31 Reset counters for consumable parts (function code: 88)
<Function>
This function is performed to reset the counter for each consumable part in the main PCB
after that has been replaced.
<Operating Procedure>
(1) Press the [8] key twice in the initial state of maintenance mode. "Reset-Laser Unit" is
displayed on the LCD.
(2) Press the [
▲
] or [
▼
] key to display the part with the counter to be reset on the LCD, and
press the [Mono Start] key.
(3) "*******OK?" is displayed on the LCD. Press the [Mono Start] key to reset the counter for
the selected part and return the display to the procedure (2). (******* represents the
name of the selected part)
(4) Press the [X] key, and the machine returns to the initial state of maintenance mode.
Selectable parts are shown in the table below.
LCD
Part name
Counter to be reset
Reset-Laser Unit
Laser unit
Printed pages counter
Reset-Fuser Unit
Fuser unit
Printed pages counter
Reset-PF Kit T1
PF kit 1
Printed pages counter
Reset-PF Kit T2
PF kit 2
Printed pages counter
Reset-PF Kit T3
PF kit 3
Printed pages counter
Reset-PF Kit T4
PF kit 4
Printed pages counter
Reset-PF Kit T5
PF kit 5
Printed pages counter
Reset-PF Kit MP
PF kit MP
Printed pages counter
Reset-LVPS
Low-voltage power supply
PCB ASSY
Irregular power supply detection counter
Содержание DCP-L5500D
Страница 42: ...2 7 Confidential 2 2 2 Scanner part Common to Legal A4 models Fig 2 5 Document feed path ...
Страница 162: ...3 2 Confidential 2 PACKING Machine Fig 3 1 Toner pad Option carton Silica gel PE bag Polystylene pad ASSY Carton ...
Страница 227: ...3 67 Confidential 6 Remove the CIS carriage from the CIS drive belt Fig 3 63 CIS drive belt CIS carriage CIS drive belt ...
Страница 343: ...5 28 Confidential Print adjustment test pattern Fig 5 6 ...
Страница 353: ...5 38 Confidential Fig 5 11 K 100 K 1 W 100 K 5 Lattice Total ...