Error code EC00
A USB device not within the specification is connected to the USB terminal, resulting in over
current.
Error code ED00
Failed to authenticate the firmware for the self test.
Error code EE00
Failed to authenticate the NVRAM for the self test.
Error code F900
The spec code was not entered correctly.
<User Check>
• Disconnect the USB device from the USB flash memory port and turn the machine OFF.
Turn the machine ON again after a while.
• Replace the USB device with a different one.
Step
Cause
Remedy
1
USB host PCB failure
Replace the USB host PCB ASSY.
2
Main PCB failure
Replace the main PCB ASSY.
<User Check>
• Turn the power switch OFF and then ON again.
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Step
Cause
Remedy
1
The power was turned OFF
while function code 74 was
running.
Reenter the spec code.
2
Main PCB failure
Replace the main PCB ASSY.