3-83
Confidential
9.22 Low-voltage power supply PCB ASSY
(1) Remove the taptite cup S M3x8 SR screw and screw cup M3x8 (black) screw to remove
the scanner ground plate.
(2) Remove the three screw cup M3x8 (black) screws, taptite bind B M4x12 screw, screw
pan M4x8 screw, washer spring 2-4, and washer 5 to remove the LV shield plate cover.
(3) Remove the LVPS insulation sheet.
Fig. 3-82
LVPS insulation sheet
LV shield plate cover
Scanner ground plate
Taptite cup S M3x8 SR
Screw cup M3×8 (black)
Screw cup M3×8
(black)
Taptite bind B M4x12
Screw pan M4x8
Washer 5
Washer spring 2-4
Содержание DCP-L5500D
Страница 42: ...2 7 Confidential 2 2 2 Scanner part Common to Legal A4 models Fig 2 5 Document feed path ...
Страница 162: ...3 2 Confidential 2 PACKING Machine Fig 3 1 Toner pad Option carton Silica gel PE bag Polystylene pad ASSY Carton ...
Страница 227: ...3 67 Confidential 6 Remove the CIS carriage from the CIS drive belt Fig 3 63 CIS drive belt CIS carriage CIS drive belt ...
Страница 343: ...5 28 Confidential Print adjustment test pattern Fig 5 6 ...