3-58
Confidential
9.12.2Panel PCB ASSY, LCD (For LCD: 4.85 inch models)
(1) Disconnect the key PCB flat cable from the panel PCB ASSY and release it from the
securing fixtures.
(2) Remove the three taptite cup B M3x10 screws. Release each hook to remove the LCD
presser from the panel cover.
(3) Remove the four taptite cup B M3x10 screws, and remove the shield plate cover from
the panel cover.
Fig. 3-52
Harness routing: Refer to
“6. Panel unit (4.85 inch model)”
.
Taptite cup B M3x10
Taptite cup B M3x10
LCD presser
Hooks
Hook
Shield plate cover
Panel cover
Key PCB flat cable
Panel PCB ASSY