White streaks
Partially shaded
Fully tinged
<User Check>
• Clean the scanner glass or first side/second side scanner glass
strip.
• Clean the document hold.
Step
Cause
Remedy
1
Dirt inside of scanner glass
Clean the inside of the scanner glass.
2
Dirt inside of first side/second side
scanner glass strip
Clean the inside of the first side/second side
scanner glass strip.
3
First or second side CIS unit failure Replace the first or second side CIS unit.
4
Scratch on scanner glass
Replace the document scanner unit.
5
Scratch on second side scanner
glass strip
Replace the ADF unit.
<User Check>
• Clean the scanner glass.
Step
Cause
Remedy
1
Dirt inside of scanner glass
Clean the inside of scanner glass.
2
Deformed document sponge
Replace the document scanner unit.
<User Check>
• Clean the scanner glass or first side/second side
scanner glass strip.
Step
Cause
Remedy
1
Incorrect white level correction data Execute "Acquire white level data (
)".
2
First or second side CIS unit failure Replace the first or second side CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Содержание DCP-L5500D
Страница 42: ...2 7 Confidential 2 2 2 Scanner part Common to Legal A4 models Fig 2 5 Document feed path ...
Страница 162: ...3 2 Confidential 2 PACKING Machine Fig 3 1 Toner pad Option carton Silica gel PE bag Polystylene pad ASSY Carton ...
Страница 227: ...3 67 Confidential 6 Remove the CIS carriage from the CIS drive belt Fig 3 63 CIS drive belt CIS carriage CIS drive belt ...
Страница 343: ...5 28 Confidential Print adjustment test pattern Fig 5 6 ...
Страница 353: ...5 38 Confidential Fig 5 11 K 100 K 1 W 100 K 5 Lattice Total ...