App.
4-38
Confidential
WSW34
(Function setting 12)
Selector
No.
Function
Setting and Specifications
1
|
3
Erasing time length of ICM
tone recorded preceding the
tone detection starting point in
the case of automatic line
disconnection due to no voice
signal received (Not used.)
No.
1 2 3
0 0 0 :
0
sec.
0 0 1 :
1
sec.
0 1 0 :
2
sec.
0 1 1 :
3
sec.
1 0 0 :
4
sec.
1 0 1 :
5
sec.
1 1 0 :
6
sec.
1 1 1 :
7
sec.
4
5
No. of CNG cycles to be
detected
(when the line is connected via
the external telephone in the
external TAD mode or via the
machine in F/T mode)
(Not used.)
No. 4 5
0 0 : 0.5
(A)
0 1 : 1
(B)
1 0 : 1.5
(C)
1 1 : 2
(D)
6
7
Number of DTMF tone signals
for inhibiting the detection of
CNG during external TAD
operation
No. 6 7
0 0 : 3
0 1 : 2
1 0 : 1
1 1 : OFF
8 Not
used.
NOTE:
Selectors 1 through 5 are applicable to models equipped with built-in TADs.
- Selectors 1 through 3: Erasing time length of ICM tone recorded preceding the tone detection starting
point in the case of automatic line disconnection due to no voice signal received
(Not used.)
If the machine has disconnected the line after detection of disconnection tone in ICM recording, it
erases tone recorded preceding the tone detection starting point for the time length set by these
selectors.
- Selectors 4 and 5: No. of CNG cycles to be detected (when the line is connected via the external
telephone in the external TAD mode or via the machine in F/T mode) (Not used.)
The machine interprets a CNG as an effective signal if it detects a CNG signal by the number of
cycles specified by these selectors when the line is connected via the external telephone in the
external TAD mode or via the machine in F/T mode.
- Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external
TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
Содержание DCP 8060
Страница 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC 8460N 8860DN 8870DW DCP 8060 8065DN ...
Страница 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Страница 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Страница 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Страница 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Страница 95: ...Confidential 4 2 Cover page sample End page sample ...
Страница 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 164: ...Confidential 5 63 5 1 46 Panel Cover ASSY 1 Remove the Panel cover ASSY Fig 5 79 Panel cover ASSY Hooks ...
Страница 185: ...Confidential 5 84 7 Remove the Support lap from the Process cover Fig 5 119 Support lap Process cover ...
Страница 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 292: ...Confidential CHAPTER 7 CLEANING ...
Страница 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Страница 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Страница 303: ...8 8 Confidential For color scanning Fig 8 3 Scanning Compensation Data List a b c d e f g h i j k l m n o p q s ...
Страница 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Страница 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 458: ...B Power Supply PCB 100V Confidential ...
Страница 459: ...B Power Supply PCB 200V Confidential ...
Страница 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...