![Brother DCP 8060 Скачать руководство пользователя страница 412](http://html.mh-extra.com/html/brother/dcp-8060/dcp-8060_servise-manual_53143412.webp)
App.
4-13
Confidential
WSW09
(Protocol definition 1)
Selector
No.
Function
Setting and Specifications
1
Frame length selection
0: 256 octets 1: 64 octets
2
Use of non-standard
commands
0:
Allowed 1:
Prohibited
3
4
No. of retries
No. 3 4
0 0 :
4
times
0 1 :
3
times
1 0 :
2
times
1 1 :
1
time
5
T5 timer
0: 300 sec.
1: 60 sec.
6
T1 timer
0: 35 sec.
1: 40 sec.
7
8
Timeout for response from
the called station in
automatic sending mode
No. 7 8
0 0
: 55 sec. (in U.S.A. and Canada
models)
60 sec. (in other models)
0
1
:
140
sec.
1 0
: 90 sec.
1 1
: 35 sec.
NOTE:
Selectors 1 through 5 are not applicable in those models which do not support ECM.
- Selector 1: Frame length selection
Usually a single frame consists of 256 octets (1 octet = 8 bits). For communications lines with
higher bit error rate, however, set selector 1 to "1" so that the machine can divide a message into
64-octet frames.
Remarks
: The error correction mode (ECM) is a facsimile transmission manner in which the
machine divides a message into frames for transmission so that if any data error occurs
on the transmission line, the machine retransmits only those frames containing the error
data.
- Selector 2: Use of non-standard commands
If this selector is set to "0," the machine can use non-standard commands (the machine’s native-
mode commands, e.g., NSF, NSC, and NSS) for communications. If it is set to "1," the machine
will use standard commands only.
- Selectors 3 and 4: No. of retries
These selectors set the number of retries in each specified modem transmission speed.
- Selector 5: T5 timer
This selector sets the time length for the T5 timer.
- Selector 6: T1 timer
This selector sets the time length for the T1 timer.
- Selectors 7 and 8: Timeout for response from the called station in automatic sending mode
If the machine (calling station) receives no response (no G3 command) from the called terminal in
automatic sending mode for the period specified by these selectors, it disconnects the line.
Содержание DCP 8060
Страница 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC 8460N 8860DN 8870DW DCP 8060 8065DN ...
Страница 19: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Страница 28: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Страница 65: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Страница 92: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Страница 95: ...Confidential 4 2 Cover page sample End page sample ...
Страница 96: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Страница 164: ...Confidential 5 63 5 1 46 Panel Cover ASSY 1 Remove the Panel cover ASSY Fig 5 79 Panel cover ASSY Hooks ...
Страница 185: ...Confidential 5 84 7 Remove the Support lap from the Process cover Fig 5 119 Support lap Process cover ...
Страница 246: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 292: ...Confidential CHAPTER 7 CLEANING ...
Страница 294: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Страница 302: ...8 7 Confidential For white and black scanning a b c d e f g h i j ...
Страница 303: ...8 8 Confidential For color scanning Fig 8 3 Scanning Compensation Data List a b c d e f g h i j k l m n o p q s ...
Страница 314: ...8 19 Confidential Cover page sample End page sample Fig 8 10 ...
Страница 323: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 458: ...B Power Supply PCB 100V Confidential ...
Страница 459: ...B Power Supply PCB 200V Confidential ...
Страница 495: ...January 06 SM FAX049 8C5B03 9 Printed in Japan ...