App. 1-39
Confidential
<WSW34>
Note:
Selectors 1 through 5 are applicable to models equipped with built-in TADs.
• Selectors 1 through 3: Erasing time length of ICM tone recorded preceding the tone
detection starting point in the case of automatic line
disconnection due to no voice signal received (Not used.)
If the machine has disconnected the line after detection of disconnection tone in ICM
recording, it erases tone recorded preceding the tone detection starting point for the time
length set by these selectors.
• Selectors 4 and 5: No. of CNG cycles to be detected (when the line is connected via
the external telephone in the external TAD mode or via the
machine in F/T mode) (Not used.)
The machine interprets a CNG as an effective signal if it detects a CNG signal by the
number of cycles specified by these selectors when the line is connected via the external
telephone in the external TAD mode or via the machine in F/T mode.
• Selectors 6 and 7:Number of DTMF tone signals for inhibiting the detection of CNG
during external TAD operation
If the machine receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
Selector No.
Function
Setting and Specifications
1
I
3
Erasing time length of ICM tone
recorded preceding the tone
detection starting point in the
case of automatic line
disconnection due to no voice
signal received (Not used.)
No. 1 2 3
0 0 0: 0 sec.
0 0 1: 1 sec.
0 1 0: 2 sec.
0 1 1: 3 sec.
1 0 0: 4 sec.
1 0 1: 5 sec.
1 1 0: 6 sec.
1 1 1: 7 sec.
4
5
No. of CNG cycles to be
detected
(when the line is connected via
the external telephone in the
external TAD mode or via the
machine in F/T mode)
(Not used.)
No. 4 5
0 0: 0.5
(A)
0 1: 1
(B)
1 0: 1.5
(C)
1 1: 2
(D)
6
7
Number of DTMF tone signals
for inhibiting the detection of
CNG during external TAD
operation
No. 6 7
0 0: 3
0 1: 2
1 0: 1
1 1: OFF
8
Not used.
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...