App. 1-26
Confidential
• Selectors 8: Limitation on CNG detection
If this selector is set to "1," the machine detects a CNG signal according to the condition
preset by selectors 2 and 3 on WSW18 after a line is connected. If it is set to "0," the
machine detects a CNG signal as long as the line is connected.
<WSW21>
Note:
• Selectors 1 through 5 are applicable to models equipped with ICM recorders.
• Selectors 6 through 8 are applicable to models equipped with TADs.
• Selectors 1 through 5: Max. waiting time for voice signal (Not used.)
In the TAD mode, the machine waits for voice signal for the time length specified by these
selectors before it automatically shifts to the facsimile message receive mode or
disconnects the line.
• Selectors 6 and 7: Taping the call (Not used.)
These selectors select whether or not to tape the call. Setting them to "1, 0" enables taping
the call without signaling to the calling station that the call is being taped.
• Selector 8: Erasure of message stored in the memory after the message transfer
Setting this selector to "0" will erase the message recorded in the memory after the
document retrieval feature transfers the message.
Selector No.
Function
Setting and Specifications
1
I
5
Max. waiting time for voice
signal (Not used.)
No. 1 2 3 4 5
0 0 0 0 0: No detection
0 0 0 0 1: 1 sec.
0 0 0 1 0: 2 sec.
0 0 0 1 1: 3 sec.
|
0 0 1 1 0: 6 sec. (Default)
|
1 1 1 1 1: 31 sec.
6
7
Taping the call (Not used.)
No. 6 7
0 0: Enable (signaling for
(A)
U.S.A.)
0 1: Enable (signaling for
(B)
countries except U.S.A.)
1 0: Enable (without signaling) (C)
1 1: Disable
(D)
8
Erasure of message stored in
the memory after the message
transfer
0: Yes
1: No
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...