App. 1-36
Confidential
<WSW31>
Note:
Selector 5 is applicable only to the U.S.A. models.
• Selector 2: Default reduction rate for failure of automatic reduction during recording
This selector sets the default reduction rate to be applied if the automatic reduction function
fails to record one-page data sent from the calling station in a single page of the current
recording paper.
If it is set to "0," the machine records one-page data at full size (100%) without reduction; if
it is set to "1," the machine records it at 70% size.
• Selector 5: Minimum ON and OFF duration of ringer signals effective in distinctive
ringing (Not used.)
The ringer pattern consists of short and long rings, e.g., short-short-long rings. This
selector sets the minimum ON and OFF duration of ringer signals that are required for the
machine to interpret ringer signals as being ON or OFF. This is to prevent components of a
ringer pattern from being misinterpreted due to chattering in distinctive ringing.
The machine monitors ringer signals at 10-ms intervals. If the signal is ON, the machine
1; if it is OFF, it counts -1. If the counter increments up to +5 or +13 when this
selector is set to "1" (90 ms) or "0" (130 ms), respectively, the machine interprets the
current signal as being ON.
If the counter returns to zero, the machine interprets the signal as being OFF.
If the Distinctive Ring is set to OFF, this selector is not effective.
Selector No.
Function
Setting and Specifications
1
Not used.
2
Default reduction rate for failure
of automatic reduction during
recording
0: 100 %
1: 75 %
3
Not used.
4
(Do not disturb this selector.)
5
Minimum ON and OFF duration
of ringer signals effective in
distinctive ringing (Not used.)
0: 130 ms
1: 90 ms
6
I
7
Not used.
8
Drum life indication
0: No
1: Yes
Содержание DCP-7030
Страница 78: ...2 2 Confidential 2 PERIODICAL PEPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 133: ...3 55 Confidential 8 12 8 ADDRESS LABEL 1 Remove the Address label from the Panel unit Fig 3 53 Address label Panel unit ...
Страница 150: ...3 72 Confidential 8 27 FILTER ASSY 1 Remove the Filter ASSY from the Main body Fig 3 72 Filter ASSY Front side ...
Страница 178: ...3 100 Confidential 8 39 RUBBER FOOT 1 Remove the two Rubber feet from the Main body Fig 3 104 Rubber foot Front side ...
Страница 201: ...5 5 Confidential Print sample Fig 5 1 ...
Страница 226: ...5 30 Confidential Location of fans Fig 5 13 Fan motor 60 unit Right side ...
Страница 233: ...6 1 Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM High voltage Power Supply PCB Circuit Diagram ...
Страница 234: ...6 2 Confidential LVPS PCB Circuit Diagram 100V ...
Страница 235: ...6 3 Confidential LVPS PCB Circuit Diagram 200V ...
Страница 239: ...6 7 Confidential Wiring Diagram ...