BES-941BC • BES-1241BC
173
Chapter 10 Troubleshooting
Symptom
Measures
ERROR C7 occurs.
• Is the lower shaft being tested in the test mode?
If so, refer to the operation method of the test mode and exit the test
mode or turn the power off once and on again.
• Turn the power off once and on again. If the same error occurs again,
replace the main PCB with a new one.
• Enter the encoder signal test mode and manually turn the main shaft
pulley.
If it is abnormally heavy, the main shaft mechanism is faulty.
• Refer to the block diagram showing the cable connections and check
to see if connection from the main shaft motor to the main PCB is
proper. Also check the connection from connectors P6 and P4 of the
main PCB to connectors P19 and P12 of the power supply PCB in the
box and the connection from connector P11 of the power PCB to the
14v terminal of the power transformer.
Main shaft rotation speed error oc-
curs.
• The bed retract sensor is not adjusted properly. Adjust it properly.
Cylinder bed position error occurs.
• Check to see if connection from connector P16 of the main PCB to
connector P10 of the power supply PCB in the control box is proper.
• Refer to the block diagram showing the cable connections and check
to see if connection from connector P4 of the BC PCB to the power
supply PCB in the control box, and connection from connector P9 of
the main PCB to connector P3 of the power supply PCB in the control
box are proper.
• Replace the power supply PCB with a new one.
• Replace the main PCB with a new one.
Power PCB error occurs.
• Refer to the block diagram showing the cable connections and check
to see if connection from connector P5 of the power PCB in the control
box to connector P1 of the power supply PCB in the power supply
base, and connection from connector P4 of the power supply PCB in
the power supply base to the 18v terminal of the power transformer are
proper.
• Check fuse F3 on the power supply PCB in the power supply base.
If it is blown, replace it with a new one. If it becomes blown again,
the 24v system circuit is faulty.
Cooling fan motor stops.
Exhaust fan motor stops.
When all three fans in the control box
stop
Presser foot down error occurs.
• Is the presser foot attached?
If not, attach it.
• Does it rise and drop immediately?
If so, adjust the presser foot sensor.
• Does the presser foot rise and make some noise for a while?
If so, check to see if connection from the presser foot sensor to the
head PCB is proper. Replace the presser foot sensor with a new one.
Replace the head PCB with a new one.
• Does the presser foot move? If it does not move at all, check to see if
connection from the presser foot motor to the head PCB is proper.
Replace the presser foot motor with a new one. Replace the head
PCB with a new one.
Содержание BES-1241BC
Страница 7: ...5 BES 941BC BES 1241BC 2 1 7 1 6 3 4 5 7 3 2 Belt cover Finger guard BES 941BC ...
Страница 13: ...11 BES 941BC BES 1241BC Setting of thread breakage sensor page 94 Setting of Machine page 97 ...
Страница 18: ...16 BES 941BC BES 1241BC ...
Страница 19: ...Chapter 1 Preparation of Embroidery Machine ...
Страница 50: ...Chapter 1 Preparation of Embroidery Machine BES 941BC BES 1241BC 48 ...
Страница 60: ...BES 941BC BES 1241BC 58 Chapter 2 Embroidering Procedures ...
Страница 125: ...Chapter 6 Operation of Machine ...
Страница 136: ...Chapter 6 Operation of Machine BES 941BC BES 1241BC 134 ...
Страница 137: ...Chapter 7 Maintenance ...
Страница 148: ...Chapter 7 Maintenance BES 941BC BES 1241BC 146 ...
Страница 149: ...Chapter 8 Standard Adjustment ...
Страница 161: ...Chapter 9 List of Error Messages ...
Страница 166: ...BES 941BC BES 1241BC 164 Chapter 9 List of Error Messages ...
Страница 179: ...Connection and Installation of Optional Equipment ...
Страница 182: ...INSTRUCTION MANUAL BROTHER INDUSTRIES LTD NAGOYA JAPAN Printed in Japan 155 941 C41 S93941 002 1999 09 H 1 ...