BES-941BC • BES-1241BC
171
Chapter 10 Troubleshooting
Symptom
Measures
• Is thread tangled in the rotary hook?
Clean the rotary hook.
• Is the lower shaft with which the error occurs rotating?
If so, check to see if connection from the lower shaft sensor PCB to
the BC PCB is proper. Adjust the lower shaft sensor. Replace the
lower shaft sensor PCB with a new one.
• If the lower shaft with which the error occurs is not rotating, check to
see if connection from the lower shaft motor to the BC PCB is proper.
Replace the lower shaft module with a new one. Replace the BC PCB
with a new one.
The lower shaft motor zero point er-
ror occurs.
• Is the rotary hook rotated manually?
This is not a fault.
• Check to see if connection from the lower shaft sensor PCB to the BC
PCB is proper. Replace the lower shaft module with a new one.
The lower shaft motor standby posi-
tion error occurs.
• Check to see if the lower shaft fan is normally rotating. If the fan is at
standstill, check to see if connection from the lower shaft fan to the BC
PCB is proper. Replace the lower shaft fan with a new one.
• If all the lower shaft fans are at standstill, check fuse F4 on the power
supply PCB in the control box.
• Is the hole next to the bed with which the error frequently occurs clogged
with dust?
If so, clean it.
• Check to see if connection from the thermister of the lower shaft module
to the BC PCB is proper.
The lower shaft overheat error oc-
curs.
• Is thread tangled in the rotary hook?
Clean the rotary hook.
• Conduct BC sensor test of the test mode.
If there is any failure, replace the lower shaft module with a new
one.
• Conduct automatic out-of-step limit measurement of BC automatic test
in the test mode.
Replace the lower shaft module with a new one if there is any fault.
• Check to see if the lower shaft fan of the head with which the error
frequently occurs is correctly rotating.
If the fan is at standstill, check to see if connection from the lower
shaft fan to the BC PCB is proper. Replace the lower shaft fan with a
new one.
• If all the lower shaft fans are at standstill, check fuse F4 on the power
supply PCB in the control box.
• Is the hole next to the bed with which the error frequently occurs clogged
with dust?
If so, clean it.
Thread is frequently tangled in the
rotary hook.
Содержание BES-1241BC
Страница 7: ...5 BES 941BC BES 1241BC 2 1 7 1 6 3 4 5 7 3 2 Belt cover Finger guard BES 941BC ...
Страница 13: ...11 BES 941BC BES 1241BC Setting of thread breakage sensor page 94 Setting of Machine page 97 ...
Страница 18: ...16 BES 941BC BES 1241BC ...
Страница 19: ...Chapter 1 Preparation of Embroidery Machine ...
Страница 50: ...Chapter 1 Preparation of Embroidery Machine BES 941BC BES 1241BC 48 ...
Страница 60: ...BES 941BC BES 1241BC 58 Chapter 2 Embroidering Procedures ...
Страница 125: ...Chapter 6 Operation of Machine ...
Страница 136: ...Chapter 6 Operation of Machine BES 941BC BES 1241BC 134 ...
Страница 137: ...Chapter 7 Maintenance ...
Страница 148: ...Chapter 7 Maintenance BES 941BC BES 1241BC 146 ...
Страница 149: ...Chapter 8 Standard Adjustment ...
Страница 161: ...Chapter 9 List of Error Messages ...
Страница 166: ...BES 941BC BES 1241BC 164 Chapter 9 List of Error Messages ...
Страница 179: ...Connection and Installation of Optional Equipment ...
Страница 182: ...INSTRUCTION MANUAL BROTHER INDUSTRIES LTD NAGOYA JAPAN Printed in Japan 155 941 C41 S93941 002 1999 09 H 1 ...