14. TABLE OF ERROR CODES
55
BE-438C
Code
Cause
Remedy
E-A0
Home position cannot be detected (malfunction
of home position sensor), or malfunction of power
supply circuit board.
Turn off the power and check the connection of home
position sensor connector P1.
E-b0
You tried to change the program number when
DIP switch A-8 was set to ON.
Press the RESET switch.
Set DIP switch A-8 to OFF before trying to change the
program number.
E-d0
Heat sink of control circuit board is abnormally
hot.
Turn off the power and clean the air intake port of the box.
E-E0
Malfunction of EEPROM (malfunction of main
circuit board).
Turn off the power, and turn it back on. If the error continually
occurs, contact a qualified service technician.
E-E1
Corrupted EEPROM data, or main PROM version
has been upgraded.
Press the RESET switch to reset the error. However, the data
(memory switches, display and user programs) will be reset
to the backup data or initialized.
E-E2
Corrupted EEPROM control information data.
Press the RESET switch to reset the error. However, the data
(memory switches, display and user programs) will all be
initialized.
E-F0
Solenoid or feed motor short-circuit (malfunction
of main circuit board), or power relay is not
operating (malfunction of power supply circuit
board).
Turn off the power and contact a qualified service technician.
E-F1
Bad connection in cable between power supply
circuit board and main circuit board.
Turn off the power and check if connectors P16 is
disconnected.
E-F2
Abnormal current detected in power supply circuit
board.
Turn off the power and contact a qualified service technician.
<Errors generated when optional equipment is connected>
Code
Cause
Remedy
E-10
Emergency stop switch was pressed.
Turn the EMERGENCY STOP switch clockwise to release
the lock, and then press the RESET switch to reset the error.
E-11
Emergency stop switch was pressed during
sewing.
Turn the EMERGENCY STOP switch clockwise to release
the lock, and then press the RESET switch to reset the error.
You can then press the STEP BACK switch to repeat the
sewing.
E-12
Emergency stop switch is being continually
pressed, or emergency switch connection error.
Turn off the power and check.
E-14
Thread breakage detected.
Turn the EMERGENCY STOP switch clockwise to release
the lock, and then press the RESET switch to reset the error.
You can then press the STEP BACK switch to repeat the
sewing.
REFERENCE
segment LED alphabet
Panel display
Text display
A
b
c
d
E
F
6
H
L
o