10. STANDARD ADJUSTMENTS
38
BE-438C
10-7-2. Adjusting the engagement of the movable knife and fixed knife
A. After the movable knife and fixed knife are properly engaged, tighten the screw as shown in Fig. 1.
B. Turn the movable knife (in the direction of the arrow) while the screw is still tightened.
C. Loosen the screw.
D. Turn the movable knife (in the direction of the arrow) while the screw is still loosened.
Repeat above steps A, B, C and D four or five times to maintain the cutting performance of the knife.
10-8. Adjusting the button clamp lift amount
The maximum button clamp lift amount is 13 mm from the top of the needle plate.
(The lift amount is adjusted 10 - 11 mm at the time of shipment.)
Remove the button clamp presser spring (1), loosen the screw (2) and adjust the button clamp holder hook (3) by moving it
up and down.
*
If the button clamp lift amount is too large, the button clamp will not be raised.
*
If the button clamp cannot be raised or lowered, error code “E-61” or “E-63” will be displayed.
2666Q
0149Q
Fig. 1
Movable knife
Fixed knife
0150Q
Cutting
edge
Cutting
edge
2949Q
Cutting
edge
Cutting
edge