CHAPTER 4 EXTENDED OPTION OUTPUT (PROGRAM)
BAS H series, Programmer
97
Adding enabling (AND) conditions to the sequence output
In the example in the previous section, option outputs No. 15 and 16 are turned on and off even when you depress the
foot pedal.
In this section, add enabling conditions to allow the output to be turned on and off only when sewing is finished.
1.
Touch
.
Load the programs which have already been written.
2.
Referring to the "Mode for operating the sewing machine" table of condition numbers (refer to page 85), set the
enabling condition for No. 15 to "Enable
setting when condition No. 6 (after sewing ends) is established". Set
it to "Disable
setting (condition No. 101 in the "Table of condition number" on page 86) when output No. 16,
which ends output of a continuous sequence is turned off".
3.
Touch
to overwrite the extended option output.
If an enabling condition has been set, the disabled status is the initial setting.
4. Display the extended option output once more, and then touch
to apply the extended option output which
was overwritten in step 3 to the sewing machine.
5.
Read sewing data to carry out sewing operation.
Confirm that the left and right work clamps (option outputs No. 15 and 16) do not operate when the foot pedal is
depressed, but they are turned on and off corresponding with the raising of the work clamps when sewing is
completed. (Confirm that the intermittent clamp is at the lowered position. Depress the start switch.)
If you set "enabling
" as the enabling condition”, you usually need to set "disabling
" as well.
In the above example, set an enabling (AND) condition at the first output No. which is to be turned on and off. Then,
set the condition number for the last on or off for the sequence as the disabling condition.
If you do not set any enabling conditions as in the previous examples, outputs are turned on and off according to the
settings made on the output setting screen.
Содержание BAS H series
Страница 8: ......
Страница 9: ...Chapter 1 Read Me ...
Страница 11: ...Chapter 2 Setting Up Your Programmer ...
Страница 17: ...Chapter 3 Programming Patterns ...
Страница 85: ...Chapter 4 Extended Option Output PROGRAM ...
Страница 119: ...Chapter 5 File Manager Functions ...
Страница 132: ...CHAPTER 5 FILE MANAGER FUNCTIONS 124 BAS H series Programmer ...
Страница 133: ...Chapter 6 Setting Functions ...