background image

 

WARNING 

 
DO NOT OPERATE THIS BRODA CHAIR WITHOUT FIRST READING AND UNDERSTANDING 
THIS MANUAL. IF FOR ANY REASON THE WARNINGS OR INSTRUCTIONS ARE UNCLEAR, 
CONTACT BRODA SEATING AT 1 (800) 668-0637 FOR CLARIFICATION. DO NOT ATTEMPT 
TO USE THIS CHAIR WITHOUT FULLY UNDERSTANDING ITS’ OPERATION, AS IT MAY 
RESULT IN INJURY OR DAMAGE. 
 

Chair: SPECIFICATIONS 

 

Item 

Standard 

 

Weight Capacity 

 

300 lbs 

 

Seat Depth 

 

18” 

 

Seat Height 

 

20”  

 

 

Seat Width 

 

19”  

 

Overall Width 

 

26” 

 

Degrees of Seat Tilt 

 

Infinitely adjustable up to 28° 

 

Arm Type 

 

Fixed 

 

Front Casters 

 

5” Swivel, total lock 

 

Rear Casters 

 

5” Swivel, (1 tracking) 

 

Weight 

Approx. 65 lbs 

 

Legrest 

Angle Adjustable, Independently 

Elevating 

 

Seat / Back Surface 

 

BRODA Comfort Tension Seating® 

 

 

 

Padding 

 

Removable Padding (seat and 

back pad, neckrest, side panels, 

legrest)  

 

 

 

GENERAL INSTRUCTIONS 

 
The instructions contained herein provide guidance on the safe and correct operation of the 
BRODA LT Tilt Chair. Safety measures as described in Section 1 must be observed when 
operating the chairs’ functions or moving the chair.  
 
Every person that is involved with the operation and maintenance of the BRODA Chair, including 
the patient’s family members, must read this instruction manual prior to moving or operating the 
functions of this chair. A copy of this instruction manual must always be available to these people. 
No person, including the patient’s family members, who is unfamiliar with or is unwilling or unable 

Содержание LT tilt

Страница 1: ...5 Operating Manual Distributor Rep This manual must be given to the caregiver responsible for this chair and its occupant Caregiver Before using this chair read this manual thoroughly and save for fut...

Страница 2: ...WARNING 8 1 9 Accidental Motion Danger of Falling or Collision WARNING 8 1 10 Improper Restraint Use Risk of Serious Injury WARNING 8 1 11 Improper Use WARNING 8 1 12 Cleaning 9 1 13 Preventative Mai...

Страница 3: ...est Angle Adjustable Independently Elevating Seat Back Surface BRODA Comfort Tension Seating Padding Removable Padding seat and back pad neckrest side panels legrest GENERAL INSTRUCTIONS The instructi...

Страница 4: ...ions that are included in this manual are very important to the safe and effective operation of the BRODA Chair Safety requirements that are detailed in Section 1 must be followed at all times BRODA a...

Страница 5: ...e professional Do not lean forward out of the chair any further than the length of the armrests Make sure the casters are pointing forward when leaning forward Otherwise the chair may tip over Do not...

Страница 6: ...ly both to the first use of the Chair and to all subsequent uses An in service on the operation and safety issues as described in this manual must be given to the patient s caregivers prior to its fir...

Страница 7: ...from pulling the chair over or pulling themselves off the seating surface and to prevent the patients from pulling moveable objects onto the chair and onto themselves We recommend that the chair be u...

Страница 8: ...and exterior doorways Placing the patient near handrails tables or stationary objects while the caster locks are in place should be done with caution and should be supervised Failure to do so may lead...

Страница 9: ...id and water Rinse with clean water and dry Step 2 Use a straight application of concentrated cleaners such as Formula 409 or Fantastik Spray Cleaner Then wipe with a clean cloth If using a hospital g...

Страница 10: ...protected Leaving the chairs outdoors could cause the paint to peel Formula 409 is a trademark of the Clorox Company Fantastik is a trademark of DowBrands Inc Trademark of the Dow Chemical Company Ivo...

Страница 11: ...nance do not use any lubricants that contain solvents Solvents will damage many of the moving components on the chair If necessary a white food grade grease lubricant may be used on the sliding compon...

Страница 12: ...caregiver with the particular safety limits of the chair It is important that if assistance is required with the use of the chair that the caregiver remember to bend their knees and keep their back st...

Страница 13: ...seat Transfer s refers to the movement of a resident into or out of a chair with the assistance of their caregiver s Mechanical Transfer s refers to the movement of a patient into or out of a chair w...

Страница 14: ...upright condition and not stacked higher than 2 boxes tall No other materials should be shipped or stored on top of a BRODA box BRODA boxes should not be placed on pallets BRODA Chairs should be ship...

Страница 15: ...local BRODA representative who supplies the chair or the HME Provider The caregiver s must adhere to the Safety Requirements at all times to ensure the safety of the patient caregivers and third parti...

Страница 16: ...ting Seat Tilt 1 Squeeze the tilt handle which is located on the push bar The tilt will be easier to operate with a patient weight in the chair 2 Raise or lower the seat tilt until the desired angle i...

Страница 17: ...r comes to an abrupt stop Check to ensure casters are clean and free of dirt Check to ensure all caster locks are functioning Check for loosening of the attachment between caster stem and housing Chec...

Страница 18: ...functional testing believes that any function is not operating correctly the chair should be taken out of service until a satisfactory functional test can be completed The caregiver or maintenance de...

Страница 19: ...uator housing 1 Loosen the nut on the bottom of the cylinder Unclip the cable from the actuator lever on the cylinder 2 Cut the cable ties that secure the cable to the frame of the chair carefully not...

Страница 20: ...cated inside the barrel of the cylinder allowing for changes in position When the operator releases the handle the valve closes and locks the cylinder in the desired position The function of the actua...

Страница 21: ...rom the vhair to make this adjustment 1 Loosen the lock nut located on the stem of the gas cylinder next to the actuator with a 17mm wrench 2 From the above instructions determine whether you want to...

Страница 22: ...rts or warranty repairs The owner may return products to BRODA for warranty replacement or repair by shipping items prepaid and insured to the factory Warranty completed at the factory includes both m...

Отзывы: