![Brocade Communications Systems NetIron CER 2024C Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/brocade-communications-systems/netiron-cer-2024c/netiron-cer-2024c_hardware-manual_2817392080.webp)
68
Brocade NetIron CES and Brocade NetIron CER Hardware Guide
53-0000080-03
10-Gigabit Ethernet module installation or replacement
5
The LEDs for Fan, PS1 and PS2 are located on the right side of the front panel for Brocade NetIron
CES and Brocade NetIron CER 2024 models (On the Brocade NetIron CES 2048 and Brocade
NetIron CER 2048 models, these LEDs are located on the left side of the front panel).
The software regularly polls the hardware for power status information. You can display the status
information from any management session. In addition, the software automatically generates a
Syslog message and SNMP trap if a status change occurs.
Displaying the status of the power supplies
You can display the status of the power supplies by entering the show chassis command at any
level of the CLI. The display shows whether a power supply is installed in the specified power supply
slot and the status of the power supply. If you are not already attached to a terminal or a PC running
terminal emulation, see
“PC or terminal attachment”
on page 46
Brocade> show chassis
*** Brocade NetIron CES 2048CX ***
---POWERS ---
Power 1 ( 3I50 - AC 504W): Installed (OK)
Power 2: not present
Total power budget for system = 504 W
--- FANS ---
Metro fan tray (fan 1): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 2): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 3): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 4): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 5): Status = OK, Speed = LOW (50%)
Metro fan tray (fan 6): Status = OK, Speed = LOW (50%)
--- TEMPERATURE READINGS ---
CPU: Board 32.50C Chip 41.6C
481XG PPCR1: Board 32.50C Chip 43.31C
481XG PPCR2: Board 29.50C Chip 41.93C
2X10G PPCR: Board 33.0C Chip 41.68C
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
Base MAC Address = 001b.ed39.0300
Brocade NetIron CES 2048CX>
Syntax: show chassis
10-Gigabit Ethernet module installation or replacement
The 2-port 10-Gigabit Ethernet modules may optionally be installed or replaced in the field on the
Brocade NetIron CES 2024C, Brocade NetIron CES 2024F, Brocade NetIron CER 2024C, Brocade
NetIron CER 2024F units. You can order the Brocade
device with a 2 x10-Gigabit module installed
at the factory, or you can upgrade your device later.
This section provides the steps for installing, removing, and replacing the 10-Gigabit Ethernet
module. You will need the following tools to perform these procedures:
•
#2 Phillips-head screwdriver
•
Electrostatic Discharge (ESD) kit
Содержание NetIron CER 2024C
Страница 12: ...xii Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 In this chapter...
Страница 60: ...48 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 PC or terminal attachment 3...
Страница 68: ...56 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 CLI Functionality 4...
Страница 86: ...74 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Fiber optic connector cleaning 5...
Страница 90: ...78 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 China A China...
Страница 100: ...88 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Danger B...