Table 10
lists the LEDs that show power status for the Brocade NetIron CES and Brocade NetIron
CER 2048 models. The LEDs for the 2048CX, 2048F, and 2048FX models are just below the
management Ethernet port on the left side of the front panel, labeled P1, P2, and Fn, left to right.
The LEDs for the 2048C are just below the console connector on the left side of the front panel,
labeled P1, P2, and Fn, left to right.
Power Supplies DC - same indications for both DC power supplies
DC
Right side of front
panel
Off
No DC power.
Amber
Supply has DC power, but output is not enabled.
Green
Supply has DC power, is enabled, and has good
output.
TABLE 10
LEDs for power for the 2048 models
LED
Position
State
Meaning
Fan (labeled Fn)
Left side of front
panel
Green
The fan tray is powered on and is operating
normal.
Amber or green
blinking
The fan tray is not plugged in.
Amber
The fan tray is plugged in but one or more fans
are faulty.
PS1 (labeled P1)
Left side of front
panel
Off
Power supply 1 is not installed or is not
providing power.
Amber
Power supply 1 is installed, but not connected
or a fault is detected.
Green
Power supply 1 is installed and is functioning
normally.
PS2 (labeled P2)
Left side of front
panel
Off
Power supply 2 is not installed or is not
providing power.
Amber
Power supply 2 is installed, but not connected
or a fault is detected.
Green
Power supply 2 is installed and is functioning
normally.
DC
Right side of front
panel
Off
No DC power.
Amber
The following possibilities:
•
The power supply has DC power, but output
is not enabled
•
The power supply is over temperature
•
The fan failed
Green
Power supply has DC power, is enabled, and has
good output.
Green blinking
Power supply has input power, but DC output is
not enabled.
TABLE 9
LEDs for power and fan status for the 2024 models (Continued)
LED
Position
State
Meaning
Содержание NetIron CER 2024C
Страница 12: ...xii Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 In this chapter...
Страница 60: ...48 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 PC or terminal attachment 3...
Страница 68: ...56 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 CLI Functionality 4...
Страница 86: ...74 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Fiber optic connector cleaning 5...
Страница 90: ...78 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 China A China...
Страница 100: ...88 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Danger B...