Brocade NetIron CES and Brocade NetIron CER Hardware Guide
53-0000080-03
Operation verification
3
Operation verification
After you have installed any redundant power supplies, verify that the device is working properly by
plugging it into a power source and verifying that it passes its self test.
If your device has more than one power supply installed, repeat this procedure for each power
supply.
Verifying proper operation
1. Connect the power cord supplied with the device to the power connector on the power supply
on the rear of the device.
2. Insert the other end into a properly grounded electrical outlet.
3. Verify that the LED for each power supply is a solid green.
4. Verify proper operation by observing the LEDs.
All the port LEDs should flash momentarily, usually in sequence, while the device performs
diagnostics. After the diagnostics are complete, the LEDs will be dark except for the ones that
are attached by cables to other devices. If the links on these cables are good and the
connected device is powered on, the link LEDs will light.
Observing the power status LEDs
Table 9
lists the LEDs that show power status for the Brocade NetIron CES and Brocade NetIron
CER 2024 models. The LEDs for the 2024 models are stacked on the right side of the front panel,
just below the console port, labeled P1, P2, and Fn, top to bottom to right.
TABLE 9
LEDs for power and fan status for the 2024 models
LED
Position
State
Meaning
Fan (labeled Fn)
Right side of front
panel
Green
The fan tray is powered on and is operating
normal
Amber or green
blinking
The fan tray is not plugged in.
Amber
The fan tray is plugged in but one or more fans
are faulty.
AC PS1 (labeled P1)
Right side of front
panel
Off
Power supply 1 is not installed or is not
providing power.
Amber
Power supply 1 is installed, but not connected
or a fault is detected.
Green
Power supply 1 is installed and is functioning
normally.
AC PS2 (labeled P2)
Right side of front
panel
Off
Power supply 2 is not installed or is not
providing power.
Amber
Power supply 2 is installed, but not connected
or a fault is detected.
Green
Power supply 2 is installed and is functioning
normally.
Содержание NetIron CER 2024C
Страница 12: ...xii Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 In this chapter...
Страница 60: ...48 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 PC or terminal attachment 3...
Страница 68: ...56 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 CLI Functionality 4...
Страница 86: ...74 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Fiber optic connector cleaning 5...
Страница 90: ...78 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 China A China...
Страница 100: ...88 Brocade NetIron CES and Brocade NetIron CER Hardware Guide 53 0000080 03 Danger B...