24
Brocade MLX Series and Brocade NetIron XMR Installation Guide
53-1004195-02
Router modules
Power supply requirements for
BR-MLX-1GCx24-X
interface modules
For power supply requirements for BR-MLX-1GCx24-X interface modules, refer to <Link>“Hardware Specifications”.
24-port 1 Gbps fiber interface module
The 24-port 1 Gbps fiber interface module is available in the following formats:
•
BR-MLX-1GFx24-X
•
BR-MLX-1GFx24-X-ML
The 24-port 1 Gbps fiber interface modules has 32 Mb of flash memory and provide 24 physical ports, through which you can connect
your router to other network routers. BR-MLX-1GFx24-X-ML supports up to 512K IPv4 routes in hardware. BR-MLX-1GFx24-X
supports up to 1M IPv4 routes in hardware. The ML version can be upgraded to a X version through a software license. Please contact
Brocade to purchase the license upgrade.
NOTE
24-port 1 Gbps fiber interface modules support 1 Gbps Copper SFP optics at 10 Mbps, 100Mbps and 1Gbps speeds.
NOTE
When you install BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML modules, you must upgrade the software on all interface
modules and management modules to the appropriate software release. For more information on the appropriate software
release refer to the Hardware Installation Notes that shipped with the modules.
NOTE
When you are replacing older modules with 24x1G modules, you must first delete the software configuration for the older module.
If you do not delete the old configuration, a configuration mismatch will occur when you install the new module. This mismatch
will be displayed in the results of the
show config
command.
NOTE
The SNMP Management Information Base (MIB) uses the Interface Index (ifIndex) to assign a unique value to each port on a
module or slot. The number of indexes that can be assigned per module is 20, 40, or 64, depending on the number of ports on
the module. When installing 24-port copper or fiber interface modules, you must change the ifIndex allocation to 64 before you
install the module, or the module will not operate properly when installed.
<Link>Figure 19 shows the front panel of the BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML fiber interface modules.
TABLE 10
BR-MLX-1GCx24-X interface module LEDs
Position
State
Meaning
LEDs located at top right and left
edge of top row ports. Left LED
for top port, right LED for
bottom port)
Solid green
A link has been established.
Green blinking
The port is transmitting and receiving packets.
Off
No link exists and the port is not transmitting or
receiving packets.
Содержание MLX Series
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Document feedback...
Страница 216: ...202 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 RJ45 procedures...
Страница 262: ...248 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Simplified Upgrade...
Страница 290: ...276 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Replacing fan assemblies...
Страница 326: ...312 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Dangers...