Managing Routers and Modules
Managing the device
You can perform these management tasks for the router:
•
Enable and disable a DC power source, if necessary.
•
Display status and temperatures of all hardware components.
•
Display the Syslog configuration and static and dynamic buffers.
•
Disable and re-enable power to interface modules.
Enabling and disabling a DC Power Source
To block the router from recognizing a DC power source (and as a result, enabling the device to recognize an AC power source), enter the
following command at the global CONFIG level of the CLI:
Brocade(config)# no use-dc-power
Syntax:
no use-dc-power
Disabling and re-enabling power to interface modules
You can disable power and re-enable power to all interface modules, or to a specified interface module using the
power-off
command in
the CLI, as shown in the following example:
Brocade# power-off lp all
Syntax:
power-off lp [all |<
slot-number
>]
•
all - disables power to all interface modules
•
slot-number
- disables power to the interface module in the specified slot. You can specify 1-4 for 4-slot routers, 1-8 for 8-slot
routers, 1-16 for 16-slot routers, and 1-32 for 32-slot routers.
NOTE
It is recommended that you do not disable power to interface modules during a software upgrade. If you try to disable power
during a software upgrade, the following message will be displayed:
Warning: There is an outstanding software download.
Do you want to continue ? (enter “y” or “n”)
Type “n” and wait until the upgrade is complete.
To re-enable power to all interfaces or to a specific interface, enter the
power-on lp
command, as shown in this example:
Brocade# power-on lp
Syntax:
power-on lp [all |<
slot-number
>]
•
all - enables power to all interface modules
•
slot-number
disables power to the interface module in the specified slot. You can specify 1-4 for 4-slot routers, 1-8 for 8-slot
routers, 1-16 for 16-slot routers, and 1-32 for 32-slot routers.
Содержание MLX Series
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Document feedback...
Страница 216: ...202 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 RJ45 procedures...
Страница 262: ...248 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Simplified Upgrade...
Страница 290: ...276 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Replacing fan assemblies...
Страница 326: ...312 Brocade MLX Series and Brocade NetIron XMR Installation Guide 53 1004195 02 Dangers...