Fabric Watch Administrator’s Guide
91
53-1002752-01
Fabric Watch Configuration Using Web Tools
9
•
Click Custom Defined to specify new settings and proceed to the next step.
6. Select the check box for the type of notification method you want to use for each event type.
The available alarm actions are:
•
ERROR_LOG
•
SNMP_TRAP
•
PORT_LOG_LOCK
•
EMAIL_ALERT
7. Click Apply.
Enabling or disabling threshold alarms for individual elements
To configure element-specific alarm settings, perform the following steps.
1. Open the Fabric Watch window.
2. In Fabric Watch Explorer, select a class.
You can set alarms for information on a switch only if that information is monitored by Fabric
Watch for that switch; not all alarm options are available for all switches.
3. Select the Threshold Configuration tab.
4. Under Area Selection, select the area with the alarms that you want to enable or disable.
5. Select the Element Configuration subtab.
6. Select an element from the Element Selection menu.
7. In the Status area:
•
To disable threshold alarms, click Disabled and click Apply. The threshold alarms are
disabled and you do not need to continue with this procedure.
•
To enable threshold alarms, click Enabled and continue with the next step.
8. Select the Triggered behavior type to receive threshold alarms only when they are triggered by
events that you defined.
9. Select a time interval in which to receive the threshold alarms from the Time Interval menu.
10. Click Apply.
11.
Optional
: Apply the selections on this panel to multiple elements simultaneously.
a. Click Apply More. The Multiple Selection dialog box displays.
b. Click the boxes next to the indices of all applicable elements.
c. Click OK.
Содержание Fabric Watch
Страница 1: ...53 1002752 01 14 December 2012 752 Fabric Watch Administrator s Guide Supporting Fabric OS v7 1 0 ...
Страница 10: ...x Fabric Watch Administrator s Guide 53 1002752 01 ...
Страница 12: ...xii Fabric Watch Administrator s Guide 53 1002752 01 ...
Страница 14: ...xiv Fabric Watch Administrator s Guide 53 1002752 01 ...
Страница 38: ...18 Fabric Watch Administrator s Guide 53 1002752 01 Fabric Watch alarm behavior 2 ...
Страница 42: ...22 Fabric Watch Administrator s Guide 53 1002752 01 Fabric Watch classes areas and elements 3 ...
Страница 56: ...36 Fabric Watch Administrator s Guide 53 1002752 01 Notification configuration 5 ...
Страница 116: ...96 Fabric Watch Administrator s Guide 53 1002752 01 Fabric Watch Configuration Using Web Tools 9 ...