3. Click the Hardware Tests tab.
4. Select PCI Loopback Test.
You can modify the following parameters:
•
Frame count: Specifies the frame count as an integer from 0 to 4,294,967,295.
•
Data pattern: Specifies the data test pattern. Must be at least one hexadecimal word.
•
Test cycle: The number should be positive and the default is 1.
5. Click Start.
Memory test
Use the BCU or the HCM to perform a memory test for the adapter.
NOTE
Performing the memory test disables the adapter.
Performing a memory test through BCU
Use the diag --memtest command to test the adapter’s memory blocks.
diag --memtest <ad_id>
where:
ad_id
ID of the adapter.
Performing a memory test through HCM
Use the Hardware Tests tab on the Diagnostics dialog box as follows to perform a memory test.
1. Launch the HCM.
2. Select Configure > Diagnostics.
3. Click the Hardware Tests tab.
4. Select Memory Test.
5. Specify the test cycle using a positive number.
6. Click Start.
Pinging Fibre Channel end points
Use the BCU and HCM to ping a Fibre Channel end point from an adapter port to determine the
basic connectivity to the remote port and monitor network latency.
NOTE
Ping testing is not supported on Solaris systems.
Содержание CNA 1010
Страница 8: ...viii Brocade Adapters Troubleshooting Guide 53 1001582 01 ...
Страница 20: ...xx Brocade Adapters Troubleshooting Guide 53 1001582 01 ...
Страница 112: ...92 Brocade Adapters Troubleshooting Guide 53 1001582 01 Persistent binding 3 ...
Страница 138: ...118 Brocade Adapters Troubleshooting Guide 53 1001582 01 HCM and Installer Message Reference B ...