166
Brocade MLXe Series Hardware Installation Guide
53-1003030-01
Managing the cooling system
5
For information about checking the current low and high temperature threshold settings for
modules and fan speeds, refer to
“Displaying temperature thresholds for modules and fan speeds”
NOTE
Adjusting fan controls out of the default setting can negatively affect the efficient cooling of blades
and may cause a blade to overheat and shutdown.
You can change the default low and high temperature thresholds for a particular module and fan
speed. For example, to change the low and high thresholds of the medium fan speed for the
management modules to 56
°
C and 72
°
s C, respectively, enter the following command at the
global CONFIG level of the CLI.
Brocade(config)# fan-threshold mp med 56 72
Syntax: fan-threshold
module
[low
high-threshold
] [med
low-threshold high-threshold
] [med-hi
low-threshold high-threshold
] [high
low-threshold high-threshold
]
For the
module
parameter, you can specify the following:
Medium-high
62
°
C
80
°
C
Medium
58
°
C
75
°
C
Low
–1
°
70
°
C
Generation 2 Interface modules Packet Processor
High
74
°
C
113
°
C
Medium-high
70
°
C
87
°
C
Medium
66
°
C
85
°
C
Low
–1
°
83
°
C
Switch fabric module
High
47
°
C
75
°
C
Medium-high
37
°
C
50
°
C
Medium
27
°
C
40
°
C
Low
–1
°
30
°
C
High-Speed Switch fabric module
High
6
2°
C
1
00°
C
Medium-high
57
°
C
70
°
C
Medium
5
3°
C
6
5°
C
Low
–1
°
60
°
C
TABLE 34
Default temperature thresholds for modules and fan speeds for Brocade MLXe devices (Continued)
Fan speed
Low temperature threshold
High temperature threshold