background image

MODELS  SMSC080 • SMSC110

Page 2

CONTROL OPERATION

HOW SYSTEM WORKS

Broan SmartSense

®

 system is design to provide recommended 

ventilation for desirable indoor air quality. Related ventilation 
requirements of *ANSI/ASHRAE Standard 62, “Ventilation for 
Acceptable Indoor Air Quality” are fulfilled when this system is 
installed accordingly. Ventilation level, which is based on home 
square footage and number of bedrooms, is easily set during 
installation. Power outages do not affect settings, since they are 
stored in power independent (nonvolatile) memory. Energy usage 
is optimized by monitoring fan on-time and adjusting automatic 
ventilation as needed. Indoor air quality is provided 24-hours a 
day, 7-days a week. 
A single Broan SmartSense

®

 system is powerful enough to fulfill 

ventilation rates for larger homes; however, it is recommended 
to use multiple installations for homes with multiple bathrooms. 
Multiple installations provide distributed ventilation throughout 
the home. Multiple installations are linked and communicate 
through home’s normal power circuits to form an indoor air quality 
network. In typical multiple installations, Master control is located 
in master bathroom. Broan and Best by Broan LinkLogic™ enabled 
range hoods and LinkLogic™ enabled electric dampers can be 
linked with SmartSense

®

 so their indoor air quality ventilation 

contribution is included.
Additional features, which are turned off at factory, include 
Vacation, Disabled, Automatic-Off, and Delayed-Off modes. 
Vacation mode temporarily disables system until Master fan is 
manually turned on. Disabled mode removes fan from automatic 
ventilation usage. Disabled mode does not affect manual operation 
and its ventilation is credited toward system level requirement, but 
Broan SmartSense

®

 will not turn it on for automatic ventilation. 

If fan is manually left on, Automatic-Off turns it off after 60-minutes. 
Delayed-Off turns fan off after 20-minutes from when Off paddle is 
pressed. Fan can be immediately turned off by pressing Off paddle 
twice. 

* American National Standards Institute / American Society of Heating, 
Refrigerating and Air-Conditioning Engineers 

HOW LED WORKS

LED works differently in Run and Program/Feature Selection 
modes.
Run Mode: LED is off when fan is off. LED is on when fan is on 
manual ventilation; turned on by pressing On paddle. LED turns 
on briefly every second (fast-blink) when fan is on automatic 
ventilation; turned on by Broan SmartSense

®

.

Program/Feature Selection Mode: LED turns on and off every second 
(slow-blink) when system is in Program or Feature Selection mode. 
LED is off when Feature associated with pressed paddle is off.  
LED is on when Feature associated with pressed paddle is on.

INDOOR AIR QUALITY NETWORK

A single Broan SmartSense

®

 system is powerful enough to fulfill 

ventilation rates for larger homes; however, it is recommended 
to use multiple installations for homes with multiple bathrooms. 
Multiple installations provide distributed ventilation throughout  
the home. 

Multiple installations communicate through a home’s electrical 
power circuits to form an indoor air quality network. Communication 
pathways are called links. For optimum link performance, wire 
multiple installations to the same electrical circuit. If installation 
on the same electrical circuit is not possible then try to keep 
multiple installations on the same electrical phase. If multiple 
installations are connected to different electrical phases, have an 
electrician install an SMSCPLR Broan SmartSense® Phase Coupler 
near circuit breaker panel.  
Multiple installations can operate independently; although, it is 
recommended to link them together as an indoor air quality network. 
If single system is installed or independent system operation is 
desired, proceed with “How To Set System Level” section.
One Broan SmartSense

®

 control is selected as system Master during 

set up. Any control can be selected as system Master, but typically 
master bathroom control is chosen. All controls are factory set as 
system Masters; therefore, installations will operate as independent 
systems at factory set system level after installation if following set 
up is not done. 
One Master control can link up to 10 Broan SmartSense

®

 and 

LinkLogic™ devices. SmartSense

®

 controls that are linked to 

Master control are called Slaves. 

HOW TO LINK SMARTSENSE

®

 SYSTEM

1. Unless another control is designated and clearly marked on 

frame, under decorative plate, or documented on this instruction 
sheet as Master control, go to master bathroom control.

2.  Put Master control in Program mode; press and hold SET button 

for 3-seconds (a beep should be heard) then release it.

  Note: In order to help with single person installation, Master 

control will wait 6-minutes in Program mode for Slave link.

3.  LED should be turning on and off every second (slow-blink); if it 

isn’t then repeat step 2.

4.  Go to first control to link as a Slave.
5. Press and hold SET button for 3-seconds (a beep should be 

heard) then release it.

6.  Fan and LED should turn on after Slave’s SET button is released. 

Note: At same time Slave turns on, Master fan turns on. 

7.  Press and release Slave’s Off paddle to manually turn fan off.
8.  If there are more Slave installations then go to next control and 

repeat steps 5 through 8; otherwise continue with next step.

  Note: In order to help with single person installation, 

 

Master control will remain in Program mode for 6-minutes after 
last Slave is linked.

9. When all Slaves are linked, exit Master Program mode; go to 

Master control, press and release SET button.

10. Master LED will fast-blink to indicate system level (see HOW 

TO SET SYSTEM LEVEL, steps 9-12) and then remain on 
steady, since fan is on. This action confirms Program mode 
exit.

11.  Press and release Master’s Off paddle to turn off LED and fan.

Содержание SmartSense SMSC080

Страница 1: ...n Labor cost savings can offset higher box costs which is usually less than a dollar over standard depth boxes Use boxes that have 18 cu in minimum volume and are at least 1 1 2 in deep All controls m...

Страница 2: ...fill ventilation rates for larger homes however it is recommended to use multiple installations for homes with multiple bathrooms Multiple installations provide distributed ventilation throughout the...

Страница 3: ...s pressed To activate Vacation Mode 1 Make sure fan and LED are off Press and release OFF PADDLE 2 Put control in Feature Selection mode Press and hold ON PADDLE approximately 10 seconds a beep should...

Страница 4: ...ly 10 seconds a beep should be heard until LED turns on and off every second slow blink 3 Release OFF PADDLE 4 Press and hold OFF PADDLE a If LED is off when OFF PADDLE is held on then Delayed Off mod...

Страница 5: ...ly usually it is used only when first setting up a system or for single unit installations Links are unique for each device pair If one end of the link is removed it is important to remove the other e...

Страница 6: ...mayor a de las cajas el ctricas de Am rica del Norte sin embargo las cajas profundas brindan un espacio de trabajo adicional lo cual facilita la instalaci n Los ahorros en el costo de mano de obra pu...

Страница 7: ...Un solo sistema SmartSense de Broan tiene la fuerza suficiente para satisfacer los ndices de ventilaci n en viviendas grandes no obstante se recomienda usar instalaciones m ltiples en viviendas con v...

Страница 8: ...trol maestro Inhabilita temporalmente el sistema SmartSense de Broan El control maestro no enciende autom ticamente su ventilador o cualquier otro ventilador del sistema Despu s de salir del modo de s...

Страница 9: ...ese de que el ventilador y el LED est n apagados Presione y suelte la PALETA OFF 2 Ponga el control en el modo de selecci n de funci n Presione y sostenga la PALETA OFF aproximadamente 10 segundos se...

Страница 10: ...nes de una sola unidad Los enlaces son exclusivos para cada par de dispositivos Si se elimina un extremo del enlace es importante eliminar el otro extremo Restaurar solo elimina los enlaces dentro de...

Страница 11: ...MODELOS SMSC080 SMSC110 P gina 11...

Страница 12: ...MODELOS SMSC080 SMSC110 P gina 12 99044621C...

Отзывы: