MODEL  QTRE100H

TYPICAL INSTALLATIONS

Housing mounted to

I-joists.

Housing mounted anywhere 

between trusses using hanger 

bars.

PLAN THE INSTALLATION

1. Choose the 

installation 

location.

The location of 

your humidity 

sensing fan is 

very important. 

Use the follow-

ing guidelines 

for best opera-

tion:

Housing mounted

anywhere between

I-joists using hanger bars.

Housing mounted to joists.

Housing mounted

anywhere between

joists using hanger bars.

Housing mounted anywhere be-

tween trusses using hanger bars.

INSTALL HOUSING & 
DUCT

1a. Mount 

housing 

to joist 

or I-joist.

 
  Use a pliers to 

bend housing 

TABS

 out to 

90

0

. Hold hous-

ing in place so 

that the hous-

ing tabs con-

tact the bottom 

of the joist. 

The housing 

mounts with 

four (4) screws 

or nails. Screw 

or nail housing 

to joist through 

lowest holes in 

each mount-

i n g   f l a n g e , 

 

then through 

highest holes. 

SPACER

(use for mounting to I-Joist)

TABS

I

-JOIST

NOTE: Mounting to 

I-JOIST

 (shown) requires use of 

SPACERS

 (included) between the highest hole of each 

mounting 

fl

 ange and the I-joist.

OR

ROOF CAP 

*

4-IN. ROUND

DUCT 

*

WALL

CAP 

*

*

 Purchase

separately

•  Locate unit above (GFCI protected circuit required) or 

within 5 feet of shower head.

•  Locate unit away from heating or cooling sources 

which can affect humidity levels.

•  Do not locate near window. Unit may respond to the 

outdoor humidity level.

•  Unit must be installed in ceiling to properly sense 

moisture.

•  Locate unit only on 

fl

 at ceilings up to 12 feet high for 

proper sensing.

•  The fan will operate most ef

fi

 ciently when located 

where the shortest possible duct run and minimum 

number of elbows will be needed.

•  Use a roof cap or wall cap that has a built-in damper 

to reduce backdrafts.

2.  Plan the wiring.

•  Plan to supply the unit with proper line voltage and  

  appropriate power cable. Power cable should be  

  routed to the switch box 

fi

 rst and then to the unit  

  (See “CONNECT WIRING” on page 3).
•  Do not operate this unit with a speed control.    

  Damage to the sensor unit will result.

4-IN. ROUND

ELBOW 

*

Содержание QTRE100H

Страница 1: ...drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements MODEL QTRE100H HUMIDITY SENSING FAN READ AND SAVE THESE INSTRUC...

Страница 2: ...st TABS I JOIST NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP 4 IN ROUND DUCT WALL CAP Purchase separatel...

Страница 3: ...nd hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL a...

Страница 4: ...vice or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended ins...

Страница 5: ...ventilateur pour de plus amples renseignements et exigences VENTILATEUR D TECTION D HUMIDIT MOD LE QTRE100H LIRE ET CONSERVER CES INSTRUCTIONS NETTOYAGE ET ENTRETIEN Installateur laisser ce manuel au...

Страница 6: ...au bas de la solive Le bo tier est install l aide de quatre 4 vis ou clous Visser ou clouer le bo tier la solive travers les trous les plus bas dans chaque patte de montage puis dans les trous plus ha...

Страница 7: ...ent de l installation Utiliser un connecteur appropri et homologu UL pour fixer le fil d alimentation la plaque de branchement Brancher les fils tel qu il est illustr dans les sch mas ci dessus BRANCH...

Страница 8: ...service normal ou b tout produit ou pi ce endommag s la suite d un mauvais usage de n gligence d un accident d un entretien inappropri ou d une r paration autre que par Broan NuTone Canada d une mauv...

Отзывы: