MODEL  QTRE100H

1b. Mount housing anywhere between 

trusses, joists, or I-joists using hanger 

bars.

 
 

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be 

used on all types of framing (I-joist, standard joist, and truss 

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. Make sure TABS face “up” as shown. 

Use the set of channel mounting holes (marked “STD”) to 

mount the housing 

fl

 ush with the bottom of the drywall. Use 

the other set of holes (not marked) to mount the housing 

fl

 ush with the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

 

Extend HANGER BARS to the width of the framing.

  Hold ventilator in place with the hanger bar tabs wrapping 

around the BOTTOM EDGE OF THE FRAMING.

 

NAIL ventilator to framing or fasten with screws (not provided) 

through HOLES near nails.

 

*

 To ensure a noise-free mount: Secure hanger bars together 

with SCREWS or use a pliers to crimp mounting channels 

tightly around hanger bars.

*

 

SCREW (2)

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE

OF FRAMING

4.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use 

proper UL approved connector to secure house wiring to 

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

ON / OFF SWITCH

(PURCHASE SEPARATELY)

ON / OFF

SWITCH

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

WHT

UNIT

ORG

BLK

WHT

GRD

WHT

BLK

WHT

BRN

HUMIDITY
CONTROL

FAN

2. Attach damper/

duct connector.

 

Snap damper / duct con-

nector onto housing. Make 

sure connector is 

fl

 ush 

with top of housing and 

damper 

fl

 ap falls closed.

3. Install

4-inch round duc-

twork.

 

Connect 4-inch round 

ductwork to damper / duct 

connector. Run ductwork 

to a roof cap or wall cap. 

Tape all ductwork con-

nections to make them 

secure and air tight.

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

WHT

UNIT

BLK

WHT

GRD

WHT

BLK

WHT

HUMIDITY
CONTROL

FAN

RED

BLK

ORG

BRN

MODEL 68W, 2-FUNCTION CONTROL

(PURCHASE SEPARATELY)

COM

HUMIDITY
CONTROL

(AUTO/OFF)

FAN

(ON/OFF)

WIRING OPTION #1

 - Allows fan to operate in automatic mode or manual mode 

(for odor control) by cycling ON/OFF switch.

WIRING OPTION #2

 - Fan can be turned ON, OFF, or set to operate automatically.

TAB

Содержание QTRE100H

Страница 1: ...drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements MODEL QTRE100H HUMIDITY SENSING FAN READ AND SAVE THESE INSTRUC...

Страница 2: ...st TABS I JOIST NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR ROOF CAP 4 IN ROUND DUCT WALL CAP Purchase separatel...

Страница 3: ...nd hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL a...

Страница 4: ...vice or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan faulty installation or installation contrary to recommended ins...

Страница 5: ...ventilateur pour de plus amples renseignements et exigences VENTILATEUR D TECTION D HUMIDIT MOD LE QTRE100H LIRE ET CONSERVER CES INSTRUCTIONS NETTOYAGE ET ENTRETIEN Installateur laisser ce manuel au...

Страница 6: ...au bas de la solive Le bo tier est install l aide de quatre 4 vis ou clous Visser ou clouer le bo tier la solive travers les trous les plus bas dans chaque patte de montage puis dans les trous plus ha...

Страница 7: ...ent de l installation Utiliser un connecteur appropri et homologu UL pour fixer le fil d alimentation la plaque de branchement Brancher les fils tel qu il est illustr dans les sch mas ci dessus BRANCH...

Страница 8: ...service normal ou b tout produit ou pi ce endommag s la suite d un mauvais usage de n gligence d un accident d un entretien inappropri ou d une r paration autre que par Broan NuTone Canada d une mauv...

Отзывы: