Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 70
Broadcom Confidential and Proprietary
-e Engineering Change
-s Serial Number
-m Manufacturing ID
-a Asset Tag
-r Part Rev
-v Voltage
-f Force PCI Mode 1:Enable 2:Disable
10.40 secfg3
cmd:
secfg3
Description:
Configure NVRAM Group 3
Syntax:
secfg3
Options:
-l Led Mode 0:Mac 1:Phy1 2:Phy2 3:S Traffic 4:Shasta Mac 5:Wireless Combo
-r Max PCI Retry 0-7, 8:Auto
-a ASF 1:Enable 2:Disable
-d Dual Mac 0:Norm 1:MacB 2:MacA 3:XBAR 4:Swap 7:SwapXBAE
-m MBA Boot Protocol 0:PXE 1:RPL 2:BOOTP
-b MBA Bootstrap Type 0:Auto 1:BBS 2:Int18 3:Int19
-t MBA Delay Time 0-15
-e Exp ROM 0:64K 1:128K 2:256K 3:512K 4:1M 5:2M 6:4M 7:8M 8:16M
-n Design Type 0:NIC 1:LOM
-m MBA Boot Protocol 0:PXE 1:RPL 2:BOOTP 3:ISCSI
10.41 secfg4
cmd:
secfg4
Description:
Configure NVRAM Group 4