Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 24
Broadcom Confidential and Proprietary
value = 1
: Selecting 10HD
value = 2
: Selecting 10FD
value = 3
: Selecting 100HD
value = 4
: Selecting 100FD
Example:
b57diag –mbas 0
: To select Auto speed mode.
-pxes <value>
Select Multiple Boot Agent Speed
value = 0
: Selecting Auto
value = 1
: Selecting 10HD
value = 2
: Selecting 10FD
value = 3
: Selecting 100HD
value = 4
: Selecting 100FD
Example:
b57diag –mbas 0
: To select Auto speed mode.
-disableeswitch Disable E-Switch.
Act like engineering mode "eswitch -f" command. Disable the E-Switch on the device that
support eswitch, such as 5756. Without this option, PHY loopback test, external loopback
test (pkttest -e), and carrier test are performed on both laptop mode and docking mode.
With this option, above tests are performed on the default port.
-h
: High Resolution (80x50) Video Mode
-p
: Print on error
-q
: Quick diagnostic mode
-asf <value>
: Enable/Disable (value = 1/0) ASF in manufacture mode
-ipmi <value> : Enable/Disable (value = 1/0) IPMI in manufacture mode
-com <value> : enable com port, value(1..4)
-errctrl <c>
: On Error -> a:abort w:wait l:loop c:cont s:skip
-ems <size>
: Enter external memory size in HEX to test