Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 134
Broadcom Confidential and Proprietary
-i Debug display of CPU code loading
-a Debug prompt after CPU code loading
-e Enable New UMP Echo Test in UMP Firmware
-d Disable New UMP Echo Test in UMP Firmware
10.211 umpcfg
cmd:
umpcfg
Description:
Configure UMP in NVRAM
Syntax:
umpcfg
1
UMP Settings
Description:
Provides the sub menu with the options described below.
0
Return to previous menu.
1
Enable/Disable SetLink
2
Enable/Disable RDIStallTimer
3
Set RDIStallTimerValue
4
DisableHostHashTable
5
Enable/Disable HostEchoControl
6
Enable/Disable Exceed_375ma_rule
7
Link Speed
0 : Return to previous menu
1 : Speed 10/100 (default)
2 : Speed ALL
3 : Speed 10
4 : Speed 100
5 : Speed 1000
6 : Duplex
7 : Auto/Force Mode
8 : Pause Capability
2
Save and Exit
Description:
Saves the modified UMP Configuration Table to the network adapter's non-volatile memory
and exists.
3
Exit without Saving
Description:
Exits without saving any changes to the UMP Configuration Table.
10.212 setump
cmd:
setump
Description:
Enable/Disable UMP
Syntax:
setump