Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 41
Broadcom Confidential and Proprietary
2.
Set number base to hex, write 0x2 to serial eeprom location 0x25
0:> radix 16
0:> sewrite 25 2
*** Write Serial EEPROM (Auto Mode) ***
10.7 secfg
cmd:
secfg
Description:
Configure Boot Code or Selfboot firmware.
All option is for Boot Code only. If selected program with defaults (-f=1), eeprom.bin
must be found in the same directory of b57diag.exe.
Syntax:
secfg
Options:
-v<n> : verbose level (0,1,2) (def=0)
-f : force to program with defaults
Example: (For Boot Code).
1 Program Serial EEPROM with defaults value and set verbose level to 0.
0:> secfg
Reading current NVRAM ... OK
Validating content...
1. MAC Address : 00:10:18:04:1a:36
2. Power Dissipated (D3:D2:D1:D0) : 10:0:0:100
3. Power Consumed (D3:D2:D1:D0) : 10:0:0:100
4. Vendor ID : 14E4
5. Vendor Device ID : 1653
6. Subsystem Vendor ID : 14E4
7. Subsystem Device ID : 1653
8. PXE (does not apply to PXE in system ROM)
{ Enable(1), Disable(2) } : Disable
9. PXE Link Speed { Auto(0),10HD(1),10FD(2)
100HD(3),100FD(4) }: Auto
10. Magic Packet WoL { Enable(1), Disable(2) } : Disable
11. Product Name : Broadcom NetXtreme Gigabit Ethernet Controller
12. Part Number : BCM95705A50
13. Engineering Change : 106679-15
14. Serial Number : 0123456789
15. Manufacturing ID : 14e4
16. Asset Tag : XYZ01234567
17. Part Revision : A0
18. Voltage { 1.3V(0), 1.8V(1) } : 1.8V
19. Force PCI Mode { Enable(1),Disable(2) } : Disable
20. PHY Type { Copper(1),Fiber(2) } : Copper
21. Led Mode { Mac Mode(0), Phy Mode1 (1), Phy Mode2 (2),
Shasta Mac Mode (3), SharedTraffic (4),
Wireless Combo (5)} : Phy Mode1
22. PHY ID ([PHY#2][PHY#3]) : 00206160
23. Max PCI Retry {0-7, 8=auto} : 8
24. Advanced firmware feature (ASF/IPMI/UMP)
{ Enable(1), Disable(2) } : Disable