Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 133
Broadcom Confidential and Proprietary
Syntax:
peclr <bridge>
10.208 pechk
cmd:
pechk
Description:
Check parity error on bridge. Defaults to current bridge.
Syntax:
pechk <bridge>
10.209 iscsiprg
cmd:
iscsiprg
Description:
Program ISCSI firmware into NVRAM. This command reads ISCSI code
from a file and program into NVRAM. There are 2 types of ISCSI firmware image. One
only contains ISCSI Boot Firmware. The other also contains ISCSI CFG Block and ISCSI
CFG Program. ISCSI Boot Firmware will be programmed by default. ISCSI CFG Block
will be programmed if either there is no ISCSI CFG Block present in NVRAM or “-c”
option has been entered. ISCSI CFG Program will be programmed only when “-p” option
has been entered.
Syntax:
iscsiprg [-f<filename>] [-c] [-p]
Options:
-f<filename> ISCSI firmware file name.
-c Forced to program ISCSI CFG FW
-p Forced to program ISCSI CFG Program.
10.210 umpecho
cmd:
umpecho
Description:
Enable/Disable UMP Echo Test function in UMP Firmware. It requires
either ump14a.bin/ump14b.bin test firmware or UMP Firmware. Options that will work
with test firmware are ‘-o’, ‘-c’, ‘-i’ and ‘-a’. Options that will work with UMP firmware
are ‘-e’ and ‘-d’.
Syntax:
umpecho [-o | -c | -i | -a] | [-e] | [-d]
Options:
-o Running UMP Echo Test with test firmware
-c Debug display of SRAM address 0xC00