background image

ee--m

maaiill::  

[email protected]   

vvooiiccee::  

360.854.9559   

ffaaxx::  

866.783.1742

8

SRC-32 Installation and Operation Manual

INSTALLATION

Pair Mode

The SRC-32 can be used to transmit the outputs from one unit to another over a seri-
al connection. The logical sense of the inputs is inverted when written to the outputs
of its corresponding unit.  Normally inputs are high and when closed go to a logic 0
when in pair mode.   When logic 0 is received, it will write logic 1 to the output.
This allows the relays connected to outputs 1-8 to come on if its corresponding input
is closed.  Multiple units can also be set up to communicate with the same number
of units on the other end of a data link.  All units must have DIPswitches 5 and 6
turned on and the unit addresses must have a corresponding unit on the other end of
the link set to the same address.  For example, if you have two units on each side set
to address 0 and 2, then the two units on the other side of the data link must also be
set to 0 and 2.  All units will automatically transmit the states of their inputs on
power up, every ten seconds and when any input changes states.  If a unit does not
receive an update from its corresponding paired unit for a period of 20 seconds, its
LCD display will begin to flash “COM - FAILURE”.   As soon as communications
is restored, the “COM – FAILURE” message will clear.

Command Additional Data Bytes Function

SRC-32 Binary Commands:

40h

RS-232 timer off

41h

RS-232 timer on

42h

Set serial speed to 2400

43h

Set serial speed to 9600

44h

Set serial speed to 19200

45h

Set serial speed to 38400

46h

Enable error & good responses

47h

Disable error & good responses

48h

N

Latch output n (00 – 1F)

49h

N

Unlatch output n (00 – 1F)

4Ah

Nt

Pulse output n (00 – 1F), 
t= time (1-63h =.1 - 9.9sec)

4Bh

N

Poll output n (00 – 1F) (see 55h)

4Ch

N

Poll input n (00 – 1F) (see 55h)

4Dh

All Output status request (see 52h)

4Eh

All Input status request (see 53h)

4Fh

Unit version request (see 54h)

Special Binary Commands for Modem Operation:

Future feature

Load AT command string for modem init.

Future feature

Load Telephone number for modem to dial if master

Future feature

Request for stored AT command (56h response)

Future feature

Request for stored telephone number (57h response)

Binary Output Response from SRC-32:

60h

nnn…n

Load AT command string for modem init.  (Future feature)

61h

nnn…n

Load Telephone number for modem to dial if master 
(Future feature)

62h

Request for stored AT command (56h response)  (Future feature)

63h

Request for stored telephone number (57h response)  (Future
feature)

Содержание SRC-32

Страница 1: ...nt Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademarkof Broadcast Tools Inc Copyright 1989 2005 by Broadcast Tools Inc Al...

Страница 2: ...ax x 866 783 1742 SRC 32 Installation and Operation Manual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Front Panel Descrip...

Страница 3: ...dous condition WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you purchased this equipment If you would like...

Страница 4: ...baud rate can be set to 2400 9600 19200 or 38400 other baud rates may be supplied This can be done using either the ASCII or binary command formats listed below Inputs can be simple contact closures...

Страница 5: ...switch or recycle the power DIP 1 2 The board address is set using Dipswitch numbers 1 and 2 in normal hex format 1 2 0 0 0 master No polling is required for status 0 1 1 1 0 2 1 1 3 DIP 3 4 Set baud...

Страница 6: ...ase S followed by the unit address and then the specific response If acknowledgments are enabled successful com mands are responded to with RRR while errors get an EEE response The syntax of each comm...

Страница 7: ...31 CR LF where input 1 is first and input 32 is last x is 1 if the corresponding input is high 0 otherwise uSR Send status of all OUTPUTS Response is SuA x x x x x x x x 32 CR LF uU Send Unit Informa...

Страница 8: ...receive an update from its corresponding paired unit for a period of 20 seconds its LCD display will begin to flash COM FAILURE As soon as communications is restored the COM FAILURE message will clea...

Страница 9: ...or output n 00h 1Fh if input n is low n 20h 3Fh if input n is high n 40h 5Fh if output n is low and n 60 7F if output n is high n cccnnnnn where ccc 000 input low 001 input hi 010 output lo 011 outpu...

Страница 10: ...BAR 4 is also suggested for the power transformer The purchase of an inexpensive uninterruptible power supply UPS will provide back up in case of power outages Check out our web site for lightning pro...

Страница 11: ...16B In 17A In 17B In 18A In 18B Top 4 In 19A In 19B In 20A In 20B In 21A In 21B Bottom 4 In 22A In 22B In 23A In 23B In 24A In 24B Top 5 In 25A In 25B In 26A In 26B In 27A In 27B Bottom 5 In 28A In 2...

Страница 12: ...Other baud rates may be requested RS 422 485 Serial Port 2400 9600 19200 38400 baud 8 data bits no parity 1 stop bit Other baud rates may be requested Ethernet Option Optional External Ethernet Devic...

Страница 13: ...I IE ES S O OR R R RE EM ME ED DI IE ES S TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIM...

Отзывы: