SPECIFICATIONS
Digital Inputs:
32 – Selectable 5 to 24 vdc optically Isolated or TTL/CMOS
5-volt logic compatible input 100 ms minimum duration.
Jumper selectable.
Relay Outputs:
16 – SPDT, 1 amp relays. Jumper selectable either N.O. or N.C.
Open Collectors:
16 – Open collector outputs. 12 vdc @ 100 ma each.
RS-232 Serial Port:
2400, 9600, 19200, 38400 baud, 8 data bits, no parity, 1 stop
bit. Other baud rates may be requested.
RS-232 Modem Port: 2400, 9600, 19200, 38400 baud, 8 data bits, no parity, 1 stop
bit. Other baud rates may be requested.
RS-422/485 Serial Port: 2400, 9600, 19200, 38400 baud, 8 data bits, no parity, 1 stop
bit. Other baud rates may be requested.
Ethernet Option:
Optional External Ethernet Device Server such as the
Broadcast Tools® SP-1.
Operation Control:
Front Panel - 16 x 2 LCD I/O Display
Interfacing:
Inputs – Removable screw terminals (Euro).
Relays/Open collectors – Removable screw terminals (Euro).
RS-232 Serial port - Modular w/cable and adapter (Supplied)
RS-232 Serial/ Modem Port - Male DB-9
RS-422 Serial port – Removable screw terminals (Euro).
Expansion port - Two, 10 position (2x5) .1” headers
Logic:
Flash microprocessor / Non-volatile memory
Power:
12 Vac @ 1 Amp / 120 Vac 50-60 Hz, “Wall Wart” Supplied.
(CE, 240 Vac 50-60 Hz optional)
Mechanical:
19” X 1.75” X 4.65”
Weight:
4 pounds