7.4.3 Starter relay ground loop inspection
Remove starter relay connector.
Inspect continuity between grey wire of connector
terminal and vehicle ground wire.
When the starter button is pressed, continuity between grey
wire of connector and vehicle ground wire shall be fine.
If there is no continuity, inspect starter button
continuity and lead wire.
7.4.4 Actuation inspection
Connect starter relay with battery and connect terminal of starter motor with multimeter.
Connect fully charged battery between black wire and green/yellow wire of relay. A “tap” sound
of operation can be heard on the relay and resistance displayed by multimeter is “zero”.
Ω